33
GA 2000EAC, GA 2005EAC
8
"?
OPERATING MANUAL
EDITION 12/ 2008
PART NO. 350741
The gun attachment (X) may only be changed by the
WAGNER Service Station.
6.1
FINISHING WORK AND CLEANING
1. Switch off control unit.
2. Relieve spray gun and unit pressure.
3. Replace material by cleansing agent.
4. Turn off air supply to the gun (on the EPG 3000 turn the air regulator to zero).
Note:
➞
If the round jet nozzle is fi tted: By means of nozzle spanner (A), loosen nozzle insert (B)
by a half turn.
➞
If the fl at jet nozzle is fi tted: Remove and clean the AirCoat nozzle
5. Thoroughly fl ush spray gun.
6. Relieve spray gun and unit pressure !
7. Clean the body of the gun with solvent which has been recommended by the paint
manufacturer and dry with a cloth or blow gun.
DANGER
Exploding gas/ air mixture!
Danger to life from flying parts and burns
Never spray into a closed container.
Earth the container.
SIHI_0008_GB
CAUTION
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
SIHI_0005_GB