5.4.5
CHANGING FROM AIRCOAT ROUND JET TO AIRCOAT FLAT JET
1. Replace paint with cleaning solvent,
actuate trigger, and thoroughly rinse
paint channel.
2. Relieve spray gun and unit pressure.
3. Secure spray gun! (remove control air
hose)
4. Unscrew nozzle nut (C).
5. Remove seal nipple (E) and nozzle
body (D) with universal spanner from
adapter (F)
6. Screw seal ring together O-ring (G) to
adapter (F) and tighten seal ring by
hand.
7. Fit Brillant-fl at jet nozzle (K) on paint
channel in the adapter (F).
8. Fit air cap (H) onto Brillant-fl at jet
nozzle (K).
Attention:
Make sure that the pins in the air cap fi t
into the grooves in the fl at nozzle.
9. Fit cap ring (I) with air cap (H) onto
spray gun body (F).
10. Adjust desired jet level by means of air
cap horns (X) and tighten cap ring (I)
by hand.
Universal spanner