29
GA 2000EAC, GA 2005EAC
!
"
"?
!
"
"?
OPERATING MANUAL
EDITION 12/ 2008
PART NO. 350741
5.4.3
CLEANING OF CLOGGED ROUND JET NOZZLES
1. Remove nozzle insert (B) with nozzle
spanner (A).
2. Fit desired nozzle insert (acc. to table
9.1 with nozzle spanner.
1. By means of nozzle spanner (A), loosen nozzle
insert (B) by a half turn.
2. Remove nozzle spanner and switch on for a
short amount of time.
3. After cleaning the nozzle retighten.
5.4.4
EXCHANGE OF AIRCOAT ROUND JET NOZZLE INSERT
DANGER
Exploding gas/ air mixture!
Danger to life from flying parts and burns
Never spray into a closed container.
Earth the container.
SIHI_0008_GB
Summary of Contents for GA 2000EAC
Page 2: ......
Page 46: ...46 GA2000EAC GA2005EAC OPERATING MANUAL EDITION 12 2008 PART NO 350741 ...
Page 55: ......