31
GA 2000EAC, GA 2005EAC
)
(
+
8
&
"?
OPERATING MANUAL
EDITION 12/ 2008
PART NO. 350741
5.4.6
REPLACING AIRCOAT FLAT JET NOZZLE
1. Switch off control unit.
2. Relieve spray gun and unit pressure!
3. Secure spray gun! (remove control air
hose)
4. Unscrew cap ring (I) and remove air
cap (H).
5. Remove AirCoat nozzle insert (K) and
brush cleaning solvent until all traces
of paint are dissolved.
6.
Assembly:
Fit nozzle insert (K) on paint
channel (F).
7. Fit air cap (H) onto fan nozzle (K);
Attention:
Make sure that the pins in the air cap fi t
into the grooves in the nozzle.
8. Fit cap ring (I) with air cap (H) onto spray
gun body (F).
9. Adjust desired jet level by means of air
cap horns (X) and tighten cap ring (I) by
hand.
5.4.7
PROTECTION OF THE GUN AGAINST POLLUTION
To protect the gun against pollution it is recommended to cover it with a plastic bag from
dirt (ever spray etc.).
Advantage:
Saving expenditure of cleaning. Extends lifetime of moving parts (needle / packing).
CAUTION
Defective AirCoat nozzle!
Insufficient paint application quality
Do not use sharp-edged objects to treat hard metal on the AirCoat nozzle.
SIHI_0020_GB