safety regulations

fc9900 Plus

hazard:  hazardouS vaporS

Paints, solvents, insecticides, and other materials 

can be harmful if inhaled or come in contact with 

body.  Vapors can cause severe nausea, fainting, 

or poisoning.

prevention:

• 

Use  a  respirator  or  mask  if  vapors  can  be  inhaled.    Read 

all  instructions  supplied  with  the  mask  to  be  sure  it  will 

provide the necessary protection.

• 

Wear protective eyewear.

• 

Wear  protective  clothing  as  required  by  coating 

manufacturer.

hazard:  Skin burn injury

Heated parts can cause severe skin burn injury.

prevention:

• 

Quick disconnect fittings on the hose and spray gun become 

hot during use.  Avoid skin contact with quick disconnect 

fittings when they are hot.  Allow quick disconnect fittings 

to cool before disconnecting the spray gun from the hose.

 

hazard:  exploSion or fire

Solvent  and  paint  fumes  can  explode  or  ignite.  

Severe injury and/or property damage can occur.

prevention:

• 

Provide  extensive  exhaust  and  fresh  air  introduction  to 

keep the air within the spray area free from accumulation 

of flammable vapors.

• 

Avoid all ignition sources such as static electricity sparks, 

electrical appliances, flames, pilot lights, hot objects, and 

sparks from connecting and disconnecting power cords or 

working light switches.

• 

Plastic  can  cause  static  sparks.    Never  hang  plastic  to 

enclose spray area.  Do not use plastic drop cloths when 

spraying flammable materials.

• 

Do not smoke in spray area.

• 

Fire  extinguisher  must  be  present  and  in  good  working 

order.

• 

Power  cord  must  be  connected  to  a  grounded  circuit 

(electric units only).

• 

Follow material and solvent manufacturer’s warnings and 

instructions.  Be familiar with the coating material’s MSDS 

sheet and technical information to ensure safe use.

• 

Use extreme caution when using materials with a flashpoint 

below 70° F (21º C). Flashpoint is the temperature that a 

fluid can produce enough vapors to ignite.

• 

The object to be coated must be earthed.

• 

Before working on the device, remove the power plug from 

the socket.

1.3 

electric Safety

Electric  models  must  be  grounded/earthed.    In  the  event 

of  an  electrical  short  circuit,  grounding/earthing  reduces 

the risk of electric shock by providing an escape wire for the 

electric current.  This product is equipped with a cord having 

an  grounding/earthing  wire  with  an  appropriate  grounding/ 

earthing  plug.  Connection  to  the  power  cord  only  through  a 

special feed point, e.g. through an error protection insallation 

with INF < 30 mA.

DANGER  —  Work  or  repairs  at  the  electrical 

equipment may only be carried out by a skilled 

electrician.  No  liability  is  assumed  for  incorrect 

installation.   Switch the unit off.  Before all repair 

work, unplug the power plug from the outlet.

Danger  of  short-circuits  caused  by  water 

ingressing  into  the  electrical  equipment.  Never 

spray down the unit with high-pressure or high-

pressure steam cleaners.

Caution  –  The  power  cord  for  this  equipment 

acts  as  an  supply  circuit  connector.  The  power 

cord  must  be  placed  near  an  easily  accessible, 

unobstructed socket-outlet.

Summary of Contents for FC9900 Plus

Page 1: ...finecoat 9900 Plus HVLP spray system owner s manual betriebsanleitung Mode d emploi Istruzioni per l uso MANUAL DE OPERA ES Instrucciones de uso I GB E F RFB D 0618 Form No 0276799B wagner group com...

Page 2: ...____________11 8 Choosing a projector set_____________ 12 8 1 Changing a projector set________________________12 9 Material reduction projector set chart_________________________________ 13 10 Remedy...

Page 3: ...ated hydrocarbon solvents such as methylene chloride and 1 1 1 trichloroethane They are not compatible with aluminum and may cause an explosion If you are unsure of a material s compatibility with alu...

Page 4: ...moke in spray area Fire extinguisher must be present and in good working order Power cord must be connected to a grounded circuit electric units only Follow material and solvent manufacturer s warning...

Page 5: ...er switch 8 Air outlet Air hose not pictured With this HVLP spray system you can achieve the highest quality professional finish possible with little or no preparation or setup time Please review all...

Page 6: ...et on your spray gun 4 Plug the turbine power cord into a grounded receptacle 5 Turn on the turbine and begin spraying 3 2 Dual Filtration System The turbine has two different air filters one for atom...

Page 7: ...ainer onto the spray gun and secure with the closing lever 6 Switch the turbo blower on 7 Point the paint spray gun at the object to be sprayed 8 Determine the settings for the spray pattern spray jet...

Page 8: ...turning the material adjustment knob Turn to the left more material Turn to the right less material Setting the amount of air fig 8 The correct setting for the amount of air is decisive for the atomi...

Page 9: ...from the object and avoid stopping spraying whilst still on the object i If the round jet setting is used the distance may be increased according to the size of the object being sprayed In case of exc...

Page 10: ...ompletely Never leave solvents in the spray gun container this may cause pressure to build up in the container Always keep the paint container seal clean of left over coating material and check regula...

Page 11: ...essurized air to blow out the contaminants For material that is not blown or knocked loose easily soak the filters in soapy water or mineral spirits Allow the filters to dry completely before placing...

Page 12: ...ype of material to be sprayed and the finish desired The chart on the following page should help you to make the right choice 8 1 Changing a projector set 1 Remove the air cap ring Fig 18 item 1 air c...

Page 13: ...d service during the warranty period return your unit and the proof of purchase to the distributor where it was purchased At our option the unit will be repaired or replaced In a continued commitment...

Page 14: ...lls Material supply by means of a commercially available pressure tank Part No 0261 023 WSL 60 Spray lance fig 24 When coating materials can be used Coating materials which due to their properties can...

Page 15: ...ee claims must be made immediately or at the latest within a period of 2 weeks The authorised specialist shop that delivered the device is entitled to accept guarantee claims Guarantee claims may also...

Page 16: ...e turbine 5 tapes 100V 110V voir la liste s par e 5 Stage turbine assembly 220V 240V see separate listing 5 stufige Turbinenanordnung 220V 240V siehe separates Verzeichnis Ensemble turbine 5 tapes 220...

Page 17: ...lsa Conjunto de turbina de 5 etapas 220V 240V consulte la lista separada 3 0524927 Silenziatore lato parete Silenciador lateral Silenciador de la pared lateral 4 0524593A Assemblaggio del silenziatore...

Page 18: ...Ersatzteilbild Illustration des pi ces de rechange FC9900 Plus GB turbine assembly D TURBINENANORDNUNG F ENSEMBLE TURBINE I ASSEMBLAGGIO DELLA TURBINA RFB CONJUNTO DA TURBINA E CONJUNTO DE TURBINA 88...

Page 19: ...r 0276878 Motor brush kit Motor B rstensatz Trousse de brosse moteur FC9900 Plus Denominazione Descri o Denominaci n 1 9810108 Dado Porca Tuerca 2 9821503 Fermadado Arruela de fixa o Arandela de segur...

Page 20: ...andle Unterer Griff Poign e inf rieure 6 9802266 Screw Schraube Vis 7 0524963 Lock washer Unterlegscheibe Rondelle Grower 8 0524553 Switch Schalter Commutateur 9 0529549 Circuit breaker switch kit 15A...

Page 21: ...ad 8 0524553 Commutatore Interruptor Interruptor 9 0524549 Kit per l interruttore di circuito 15 A 100V 110V Kit do interruptor do disjuntor 15 A 100V 110V Kit del conmutador del interruptor autom tic...

Page 22: ...de rechange FC9900 Plus GB lower housing assembly D UNTERE GEH USEANORDNUNG F ENSEMBLE BO TIER INF RIEUR I ASSEMBLAGGIO DEL VANO DI ALLOGGIAMENTO INFERIORE RFB CONJUNTO DO COMPARTIMENTO INFERIOR E CON...

Page 23: ...chraube Vis FC9900 Plus Denominazione Descri o Denominaci n 1 0277278 Protezione dell acqua Protetor de gua Protector de agua 2 9805387 Vite Parafuso Tornillo 3 0277443 Coperchio della cassetta di spu...

Page 24: ...900 Plus GB wiring diagram D SCHALTPLAN F DIAGRAMME DU C BLAGE I SCHEMA DI CABLAGGIO RFB DIAGRAMA DE CONEX ES E DIAGRAMA DE CABLEADO 94 1 2 3 4 6 5 0276859 0276860 0276863 0276862 0524598 9850577 0276...

Page 25: ...277472 Commutatore del flusso d aria Interruptor de fluxo de ar Interruptor del flujo de aire 5 Cavo di alimentazione Cabo de energia Cable de alimentaci n 6 Turbina Turbina Turbina FC9900 Plus Descri...

Page 26: ...E est jointe ce produit Elle peut tre command e au besoin sous le num ro de commande 2389561 I Dichiarazione di conformit UE Dichiariamo sotto la nostra esclusiva responsabilit che il presente prodott...

Page 27: ...nt 2006 42 EG 2014 30 EU 2011 65 EU 2012 19 EU Anv nta harmoniserade normer EN ISO 12100 EN 1953 EN 60204 1 EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 EN 61000 6 3 EU konformitetsf rklaringen medf ljer pr...

Page 28: ...ement nous Indicazione per lo smaltimento Secondo la direttiva europea 2002 96 CE per lo smaltimento di vecchi apparecchi elettrici e la sua conversione nel diritto nazionale questo prodotto non va sm...

Page 29: ...de Ratingen J Wagner GmbH Service St tzpunkt Siemensstra e 6 10 40885 Ratingen Tel 0 21 02 3 10 37 Telefax 0 21 02 3 43 95 N rnberg Grimmer GmbH Starenweg 28 91126 Schwabach Tel 0 91 22 7 94 73 Telef...

Page 30: ...Wagner International AG Industriestrasse 22 9450 Altst tten Schweiz Tel 41 71 7 57 22 11 Telefax 41 71 7 57 22 22 wagner wagner group ch F Euromair Antony S A V Ile de France 12 14 av F Sommer 92160...

Reviews: