37
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
5.3
START UP
5.3.1
GENERAL RULES FOR HANDLING THE HIGH ROTATION ATOMIZER
➞
Read the safety regulations in chap. 2.
➞
The air conduction of the shaping area is also decisive for the evenness of the atomizer
cloud. Check the distributor ring and outer ring (in particular the narrow annular gap)
for damage and soiling. If necessary, the parts have to be cleaned (dismantled, if appli-
cable) or replaced completely.
➞
Depending of the material used the fl ushing material share can be changed by axial
adjustment of the material tube inside or outside the distributor.
- Carry out the basic setting using the adjusting part.
- Set the material tube in the range of ±½ rotation.
SIHI_0084_GB
DANGER
Cutting effect of rapidly rotating edges !
Danger of injury through touching the rapidly rotating bell
Ensure that the bell stands still before any contact by persons.
Secure the atomizer against actuation.
SIHI_0085_GB
WARNING
Unintentional putting into operation!
Risk of injury
Before all work on the unit and in the event of work interruptions:
Switch off the high-voltage generation.
Relieve the pressure from the spray gun and unit.
Secure the atomizer against actuation.
SIHI_0083_GB
DANGER
High voltage field!
Danger to life from malfunctioning heart pacemakers
Ensure that persons with heart pacemakers:
Do not work with the electrostatic spray gun.
Remain outside the area of the electrostatic spray gun/workpiece.