75
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
Mount the stay bars and bearing tube
➞
Moisten the ends of the bearing tubes (9) with Loctite 542 slightly and insert them
into the adapter plate (10).
➞
Insert the clamping piece (2) at the ends of the stay bars (9)
➞
Moisten the ends of threaded joints (5) and (6), of air connections (7) and ends of
the connection plugs (8) slightly with Loctite 542 and insert them into the clamping
piece (2).
➞
Screw the bearing tube (1) into the clamping piece (2).
➞
Tighten the nuts for the bearing tube (4).
8.4.2
ASSEMBLY BEARING TUBE / CLAMP RODS
SIHI_0107_GB
CAUTION
Damage to the turbine !
Soiling of the supply lines, in particular of the bearing air cause damage to the turbine
Stay bars and connection nipples are to be bonded and sealed with Loctite 542
Be sure to avoid soiling of the supply lines through the excessive use of bonding
agent!
Do not under any circumstances use Teflon tape or similar thread sealing means.