47
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
5.4.6
REPLACING THE AIR CONDUCTION
Note:
The bell, distributor and air conduction are interdependent in size.
Three diameter sizes are offered for the bell, distributor and air conduction.
➞
Ø 36 mm; 1.42 inch
➞
Ø 50 mm; 1.97 inch
➞
Ø 70 mm; 2.76 inch
If you change the bell diameter, the distributor and air conduction have to be replaced as
well!
SIHI_0085_GB
WARNING
Unintentional putting into operation!
Risk of injury
Before all work on the unit and in the event of work interruptions:
Switch off the high-voltage generation.
Relieve the pressure from the spray gun and unit.
Secure the atomizer against actuation.
SIHI_0090_GB
CAUTION
Impurities of the air conduction !
Blocking of the annular gap and of the distributor channels, hardening of the materials
in the air conduction
Flush the distributor channels and air conduction with a suitable cleaning agent.
SIHI_0091_GB
CAUTION
Damage to the air conduction!
Damage to the air conduction through incorrect handling and incorrect tool usage
Only dismount the air conduction using the original tool in order to prevent damage.
Only mount the air conduction by hand in order to prevent damage.