background image

WAFER GSM-RELAY REMOTE CONTROL UNIT 

http://www.waferlife.com 

#PWD123456#OUT=110101  (

PC$PHONE)

 

Where the number is 1 or 0 to ON or OFF the relay.

 

Acknowledge

:

 

#PWD123456#OUT=110101 OK 

(4)Check the relay status 

#PWD123456#OUT?  

(

PC$PHONE) 

Check the status of all the relay

 

Acknowledge

:

   

OUT 111000        (the Number “1” means RELAY ON and “0” means RELAY OFF) 

 

#RLY Temporary latching of output relays (Only Can control from RELAY2 to RELAY6) 

This command allows the temporarily switch on the Relays for up to 65,000 seconds and receive 
confirmation SMS text alerts when the Relays switch on and off   

y

 

To activate relay 1 for 60 seconds you would send the following SMS text message to the unit

   

#PWD123456#RLY2=0005    (From RLY2 to RLY6) 

Where 2 indicates the relay number and 0005 is the time in seconds and should be entered in a 5 
digit format as shown 

The administrator number

 will receive the following confirmation text message from the unit

   

OUT2 Timer Start ON for 5 Seconds    OK 

when the relay 1 switches on, t

he administrator number will receiver the

 following message when 

the relay switches off

 

OUT2 Timer OFF OK 

Note: Relay1 cann’t be controlled by the RLY command, if you want to control the Relay1 at a temporary 

latching timer, you can setup a suitable GOT timer,and use the phone calling to control directly. 

 
#CSQ 
Check GSM signal quality

.  

(PC$PHONE)

 

This command is useful to see what is the GSM network signal level your GSM-RELAY6 is 
receiving. It ranges from 0 to 32 (if it is 0 we doubt it will never answer...). You should have a 
signal above 12 to be sure of being able to control the relay sets in any condition. Better if below 
12. You should try to add an external antenna. 
 

#PWD123456#CSQ? 

Acknowledge:

 

CSQ IS 23

 

 

#PWD123456#STATUS? 

Acknowledge:

 

ACM=ON,REPLY=ON,REPORT=OFF,RELAY=MODE0,GOT=05S,CSQ=7,IN=111111,O
UT=0000000 

 

DTMF working mode 
#PWD123456#A1      and      #PWD123456#A2 

This command is used to setup the device to Normal “Dial to control mode” (A1) or “DTMF 
mode” (A2). If work at DTMF mode (A2), When authorized user dial the GSM-RELAY6, device 
will pickup the phone and then user can press the keypad on the phone to control the separate 
relay output “only work with MODE0” 

( Press the Number and end with “##” to control separate relay, For example,press “6##” to 

Summary of Contents for GSM-RELAY6

Page 1: ...WAFER GSM RELAY REMOTE CONTROL UNIT http www waferlife com GSM RELAY6 MANUAL V1 1 From 2018 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...has 6 Relay switch output and 6 alarm input port CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM RELAY6 6 channels 230V 10A 50Hz relay contacts 6 alarm input port for separate switch type sensor input...

Page 3: ...rchased separately with 3m cable You should then insert the SIM Card of the operator you want to use with the right direction according to the following pictures Note You must remove the PIN request f...

Page 4: ...e password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be...

Page 5: ...program 3446665555 If your number appears as 85261143815 you should not program the country code 852 If your number has only 17 digits or less it is not a problem The important thing is that you don...

Page 6: ...d to Second or Minute PWD123456 TIMER DELAY AT MILLISECOND PWD123456 TIMER DELAY AT SECOND PWD123456 TIMER DELAY AT MINUTE MODE Relay Operation Mode SETUP PC PHONE Only for NO 1 Relay PWD123456 MODE0...

Page 7: ...will receiver the following message when the relay switches off OUT2 Timer OFF OK Note Relay1 cann t be controlled by the RLY command if you want to control the Relay1 at a temporary latching timer y...

Page 8: ...user only need to send the sms open1 and when received this sms OUT1 will be ON PWD123456 OUT1 ON TEXT XXXX PWD123456 OUT1 OFF TEXT XXXX PWD123456 OUT1 ON REPLY TEXT XXXX PWD123456 OUT1 OFF REPLY TEXT...

Page 9: ...RLY2 REPLY TEXT WSDRLY2 OK RLY3 TEXT WSDRLY3 RLY3 REPLY TEXT WSDRLY3 OK RLY4 TEXT WSDRLY4 RLY4 REPLY TEXT WSDRLY4 OK RLY5 TEXT WSDRLY5 RLY5 REPLY TEXT WSDRLY5 OK RLY6 TEXT WSDRLY6 RLY6 REPLY TEXT WSD...

Page 10: ...00 4 Config the SMS TEXT PC PWD123456 UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX Acknowledge UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX OKAY When the Alarm input is triggered the...

Page 11: ...y to move to another place to test If still cann t registered to the GSM net try to contact wafer to get the technical support When LED D6 is flashing slowly try to call the SIM card the calling statu...

Page 12: ...ach relay output has NO and COM contacts Note Power supply for the each load mustn t exceed 30VDC 10A or 230VAC 10A Warning GSM RELAY6 device only work as a high power switch don t power the LOAD dire...