as the REPORT phone number, that means if you enable the REPORT function,then every report event 

happen,then would send the REPORT SMS to this number 

(1)You can setup the alarm phone number when have the alarm information input 

#PWD123456#ALARM01=13818120592  

(

PC$PHONE)

 

Where 01 is the position in the list

 

Acknowledge

: ALARM01 SET TO 61143815 OK 

When the number is seted to 000000,that means delete the number in this position 

(2)

 check which is the number in a place of the alarm phone list:

 

#PWD123456#ALARM01?  

(PC$PHONE)

 

Acknowledge

: ALARM01 IS 61143815 OK 

(3)

 List all numbers in the alarm phone list:

 

#PWD123456#ALARM=ALL?  

(PC$PHONE)

 

Acknowledge

: ALARM IS XXXXX:XXXX:XXXXXXX:0000:0000 

(Will show total five numbers, if no effective number,that will be replaced with 0000 ) 

(4) Config the SMS TEXT :   

(PC)

 

#PWD123456#UDI1:XXX, UDI2:XXX, UDI3:XXX, UDI4:XXX, UDI5:XXX, UDI6:XXX 

Acknowledge

: UDI1:XXX, UDI2:XXX, UDI3:XXX, UDI4:XXX, UDI5:XXX, UDI6:XXX OKAY

 

(When the Alarm input is triggered,then will send the   
SMS you already setted with this UDI command) 
Also user can use separate command to setup for each input 

#PWD123456#UDI1:XXX 

- - - - - - - 

#PWD123456#UDI6:XXX

 

Check the text    set 

#PWD123456#UDI1?   Or  #PWD123456#UDI2?    . . . . . .  

(From UDI1 to UDI6 )

 

Acknowledge:

   

UDI1:ABC1 or    UDI2:ABC2 . . . . . . 

 

About the power failure alarm: 

(1) About the battery: Should use the 3.7V Polymer lion echargeable battery 

(2) About the alert SMS: When the main power supply failure, will send the alert SMS to the ALARM01 

number. 

Program software: 

Please download from the product link:   

http://www.waferlife.com/en/GSM-RELAY6.html 

On board Reset: 

Press and hold the button for around 10 second,then the board would reseted,and the following 
data would be reseted to: 
Password:123456

 

From WHL01 to WHL10 would be cleared 
ACM=OFF, REPLY=ON, MODE=MODE0, GOT=3S, Relay Output=0000000 

 

Summary of Contents for GSM-RELAY6

Page 1: ...WAFER GSM RELAY REMOTE CONTROL UNIT http www waferlife com GSM RELAY6 MANUAL V1 1 From 2018 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...has 6 Relay switch output and 6 alarm input port CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM RELAY6 6 channels 230V 10A 50Hz relay contacts 6 alarm input port for separate switch type sensor input...

Page 3: ...rchased separately with 3m cable You should then insert the SIM Card of the operator you want to use with the right direction according to the following pictures Note You must remove the PIN request f...

Page 4: ...e password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be...

Page 5: ...program 3446665555 If your number appears as 85261143815 you should not program the country code 852 If your number has only 17 digits or less it is not a problem The important thing is that you don...

Page 6: ...d to Second or Minute PWD123456 TIMER DELAY AT MILLISECOND PWD123456 TIMER DELAY AT SECOND PWD123456 TIMER DELAY AT MINUTE MODE Relay Operation Mode SETUP PC PHONE Only for NO 1 Relay PWD123456 MODE0...

Page 7: ...will receiver the following message when the relay switches off OUT2 Timer OFF OK Note Relay1 cann t be controlled by the RLY command if you want to control the Relay1 at a temporary latching timer y...

Page 8: ...user only need to send the sms open1 and when received this sms OUT1 will be ON PWD123456 OUT1 ON TEXT XXXX PWD123456 OUT1 OFF TEXT XXXX PWD123456 OUT1 ON REPLY TEXT XXXX PWD123456 OUT1 OFF REPLY TEXT...

Page 9: ...RLY2 REPLY TEXT WSDRLY2 OK RLY3 TEXT WSDRLY3 RLY3 REPLY TEXT WSDRLY3 OK RLY4 TEXT WSDRLY4 RLY4 REPLY TEXT WSDRLY4 OK RLY5 TEXT WSDRLY5 RLY5 REPLY TEXT WSDRLY5 OK RLY6 TEXT WSDRLY6 RLY6 REPLY TEXT WSD...

Page 10: ...00 4 Config the SMS TEXT PC PWD123456 UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX Acknowledge UDI1 XXX UDI2 XXX UDI3 XXX UDI4 XXX UDI5 XXX UDI6 XXX OKAY When the Alarm input is triggered the...

Page 11: ...y to move to another place to test If still cann t registered to the GSM net try to contact wafer to get the technical support When LED D6 is flashing slowly try to call the SIM card the calling statu...

Page 12: ...ach relay output has NO and COM contacts Note Power supply for the each load mustn t exceed 30VDC 10A or 230VAC 10A Warning GSM RELAY6 device only work as a high power switch don t power the LOAD dire...

Reviews: