WAFER GSM-RELAY REMOTE CONTROL UNIT
http://www.waferlife.com
as the REPORT phone number, that means if you enable the REPORT function,then every report event
happen,then would send the REPORT SMS to this number
(1)You can setup the alarm phone number when have the alarm information input
#PWD123456#ALARM01=13818120592
(
PC$PHONE)
Where 01 is the position in the list
Acknowledge
: ALARM01 SET TO 61143815 OK
When the number is seted to 000000,that means delete the number in this position
(2)
check which is the number in a place of the alarm phone list:
#PWD123456#ALARM01?
(PC$PHONE)
Acknowledge
: ALARM01 IS 61143815 OK
(3)
List all numbers in the alarm phone list:
#PWD123456#ALARM=ALL?
(PC$PHONE)
Acknowledge
: ALARM IS XXXXX:XXXX:XXXXXXX:0000:0000
(Will show total five numbers, if no effective number,that will be replaced with 0000 )
(4) Config the SMS TEXT :
(PC)
#PWD123456#UDI1:XXX, UDI2:XXX, UDI3:XXX, UDI4:XXX, UDI5:XXX, UDI6:XXX
Acknowledge
: UDI1:XXX, UDI2:XXX, UDI3:XXX, UDI4:XXX, UDI5:XXX, UDI6:XXX OKAY
(When the Alarm input is triggered,then will send the
SMS you already setted with this UDI command)
Also user can use separate command to setup for each input
#PWD123456#UDI1:XXX
- - - - - - -
#PWD123456#UDI6:XXX
Check the text set
#PWD123456#UDI1? Or #PWD123456#UDI2? . . . . . .
(From UDI1 to UDI6 )
Acknowledge:
UDI1:ABC1 or UDI2:ABC2 . . . . . .
About the power failure alarm:
(1) About the battery: Should use the 3.7V Polymer lion echargeable battery
(2) About the alert SMS: When the main power supply failure, will send the alert SMS to the ALARM01
number.
Program software:
Please download from the product link:
http://www.waferlife.com/en/GSM-RELAY6.html
On board Reset:
Press and hold the button for around 10 second,then the board would reseted,and the following
data would be reseted to:
Password:123456
,
From WHL01 to WHL10 would be cleared
ACM=OFF, REPLY=ON, MODE=MODE0, GOT=3S, Relay Output=0000000