Using the DC kit
DC-Kit3
32
e
Caution!
CA2500, B2200:
the inverter may be damaged.
If you are operating the system on the 230 V mains and the auto-
matic air conditioner or the heating is on, make sure that the invert-
er is switched off and stays switched off.
The inverter is not designed for the amount of power an active heat-
ing system requires. If the 230 V mains power fails, the inverter
would then take over supplying the power.
8.1
Switching on the system
Observe the following instructions before you switch on the system:
z
Air the vehicle.
z
Make sure that the ventilation slots on the air nozzles and the fan of the
components are not covered up.
z
Make sure that all the housings and cables are not damaged and that all
the insulation is intact.
z
Compare the existing supply voltage with the technical data.
z
Do not insert any fingers or objects into component openings.
I
Note
CA2500, B2200:
the remote control for the roof air conditioner can
only be used if the air conditioning is supplied with 230 V mains net-
work or with the inverter.
Stationary mode: 230 V~ mains operation
The system is supplied with 230 V~ from the mains. Leave the inverter
switched off.
The VS-230-2 priority circuit is supplied with power and supplies the second
socket with power for any connected consumer units.
DC-Kit3.book Seite 32 Freitag, 13. Juni 2008 3:24 15
Summary of Contents for DC-Kit3
Page 3: ...DC Kit3 3 1 CA1000 1 2 DC Kit3 book Seite 3 Freitag 13 Juni 2008 3 24 15...
Page 4: ...DC Kit3 4 2 1 3 4 CA2500 A B 5 DC Kit3 book Seite 4 Freitag 13 Juni 2008 3 24 15...
Page 5: ...DC Kit3 5 6 B2200 7 DC Kit3 book Seite 5 Freitag 13 Juni 2008 3 24 15...
Page 6: ...DC Kit3 6 1 8 DC Kit3 book Seite 6 Freitag 13 Juni 2008 3 24 15...
Page 159: ...DC Kit3 book Seite 2 Freitag 13 Juni 2008 3 24 15...