DC-Kit3
Using the DC kit
31
7.7
Connecting the DC kit to the power supply
➤
Check that all the connections have been made in accordance with the
instructions.
➤
Check that the roof air conditioner is closed properly.
➤
Connect the electrical connections of the components (
ECL-102).
➤
Connect the 230 V roof air conditioner to the VS-230-2 priority circuit
(
VS-230-2).
➤
Connect the positive battery cables to the batteries.
➤
Check the following are working properly:
– Check the on and off values for the charging voltage regulator
– Check the priority circuit
– Check the second socket on the priority circuit switches off in driving
mode
– Switch on the air conditioning in driving mode (
air conditioning)
– Switch on the air conditioning on mains operation
➤
Only CA1000:
adapt the roof air conditioner software to AC/DC operation
(
CA1000).
8
Using the DC kit
The DC-Kit3 consists of several components, each with its own installation
and operating manual. Use the installation and operating manuals for the
components and make sure you are familiar with the individual devices.
This chapter contains information on operating the overall system. This op-
erating manual does
not
replace any information contained in the installation
and operating instructions for the components.
e
Caution!
CA2500, B2200, HB2500:
the inverter may be damaged.
Ensure that these models are
not
used in the air conditioning or
heating modes for driving. The inverter is not designed for generat-
ing this amount of power.
DC-Kit3.book Seite 31 Freitag, 13. Juni 2008 3:24 15
Summary of Contents for DC-Kit3
Page 3: ...DC Kit3 3 1 CA1000 1 2 DC Kit3 book Seite 3 Freitag 13 Juni 2008 3 24 15...
Page 4: ...DC Kit3 4 2 1 3 4 CA2500 A B 5 DC Kit3 book Seite 4 Freitag 13 Juni 2008 3 24 15...
Page 5: ...DC Kit3 5 6 B2200 7 DC Kit3 book Seite 5 Freitag 13 Juni 2008 3 24 15...
Page 6: ...DC Kit3 6 1 8 DC Kit3 book Seite 6 Freitag 13 Juni 2008 3 24 15...
Page 159: ...DC Kit3 book Seite 2 Freitag 13 Juni 2008 3 24 15...