GH 3500
Maintenance
Operator's manual
21
7
Maintenance
7.1
Maintenance schedule
Have worn or damaged components replaced immediately!
WARNING
Danger of poisoning by exhaust fumes!
Exhaust fumes contain toxic carbon monoxide that can lead to unconscious-
ness or death.
Always switch off the engine during maintenance work!
Task
Daily
before
operation
After the
first
20 hours
Weekly or
every
25 hours
Monthly
or every
100 hours
Annually
or every
300 hours
Clean the connections
Check the fuel:
- fuel level of tank
- tank for leaks
- lines for leaks
Checking engine oil level
Clean air filter
Changing the engine oil
Clean fuel filter
Check and clean the spark plug
Replace the spark plug