GH 3500
Troubleshooting
Operator's manual
27
8
Troubleshooting
Generator
Engine
Malfunction
Cause
Remedy
No voltage
(or unstable)
Cable damage or contact prob-
lem
Have it repaired
Short circuit in the stator coil
Have coil replaced
Abnormal noises
(metallic noises or similar)
Shaft bearing defective
Have bearing replaced
Contact between rotor and sta-
tor
Have it repaired
Vibrations
Unstable position
Move machine to a stable posi-
tion
Shaft bearing defective
Have bearing replaced
Malfunction
Cause
Remedy
Engine does not start
Fuel tank empty
Top off with fuel
Fuel tap closed
Open the fuel tap
Engine switch set to "OFF".
Set the engine switch to "ON"
Motor oil level "too low"
because the machine is lean-
ing (automatic oil shut off)
Position the machine horizon-
tally
Motor oil level too low (auto-
matic oil shut off)
Top off with engine oil
Spark plug
Clean, set electrode gap, or
replace
Engine does not turn
Engine damage
Repair engine or have it
replaced
Engine not running smoothly
Air filter dirty
Clean air filter
Fuel filter dirty
Clean fuel filter
Spark plug
Clean, set electrode gap, or
replace