background image

/

User Manual

- English -

Summary of Contents for H2CAP

Page 1: ... User Manual English ...

Page 2: ...s 5 How to Operate the H2CAP 5 1 Before First Use 5 2 How to Run Cleaning Mode Vid 5 3 How to Produce Hydrogen Water Vid 5 4 How to Do the Dissolved Hydrogen DH Test Vid 6 Storage and Maintenance Vid 7 Specification Videos can be found at www h2cap com For more information about the H2CAP check out our Q A at our website ...

Page 3: ...rine and ozone Plus these allow the H2CAP to produce hydrogen water with 1 000ppb 1 500ppb that can last longer Fortheuserstotestitsperformance theH2CAPpackagecomes with the test kit that can measure the DH of the hydrogen water For user convenience additional accessories such as the Descaler and test reagent are available for sale The H2CAP was certified by Japan Hydrogen Water Promotion Associat...

Page 4: ...2 Product Composition Accessories 3RXFK 3 86 FDEOH 7ULWDQ RWWOH HVFDOHU 0DQXDO 5HDJHQW LW HVFDOHU 6HW SFV 7HVW 5HDJHQW SFV ɘ Product components may vary depending on the package type ...

Page 5: ...nge LED Blinking Quick blink of Orange LED Indication Producing hydrogenWater Ongoing Cleaning mode Hydrogen water produced or cleaning completed Hydrogen water produced cleaning is required System Error Upper Cap Case USB Port ˠ Bottom Cap ˡ Membrane ˢ Electrode Plate ˣ Sealing O ring ˤ Warranty Seal Sticker ...

Page 6: ...ach the H2CAP too tightly to the bottle Be careful not to damage the electrode plate and the membrane Once they are damaged leakage may occur and free warranties will not be available Use bottles that are compatible with the H2CAP 28mm 30mm Using without any water may damage the product Clean promptly when notified with the cleaning alarm to maintain the best performance Do not consume the Descale...

Page 7: ...ve the white plastic plug at the center of the bottom cap H2CAP comes with small amount of water on the electrode plate to keep the product moisturized Run the cleaning mode before using the product for the first time Check 5 2 to learn the detailed cleaning mode A Noise of hydrogen gas evaporation may occur upon opening the cap after producing hydrogen HVNWRS DSWRS 6PDUWSKRQH KDUJHU 6PDUWSKRQHV 3...

Page 8: ...hen reconnect The cleaning mode will start automatically and turn off after 2mins Once the cleaning mode is completed dispose the water and rinse 2 to 3 times with clean water Use only the Descaler provided One sachet at one time Using other cleaning tools may damage the product Do not submerge the product in the water for cleaning purposes Youmayrefertoourvideosatwww h2cap comforguideline Cleanin...

Page 9: ...pending on the condition of the water Refer to the specification for details Once completed the orange LED will turn on If left not opened for a long time after the hydrogen water production hydrogen gas pressure may cause small drops of water to come out from the bottom cap Running this mode 2 times will produce hydrogen water reaching up to 1 500ppb Using alkaline water or mineral water will pro...

Page 10: ...1 drop at a time The water contains 1 000ppb 1 100ppb of hydrogen if they turn blue on the 11th drop One drop equals 100ppb Slightly shake the test bottle every time the reagent is dropped DH test results may vary depending on the environment Use the hydrogen meter for exact results For more exact results do the test after running the cleaning mode Do not reuse the reagent once opened Youmayrefert...

Page 11: ...1 drop at a time The water contains 1 000ppb 1 100ppb of hydrogen if they turn blue on the 11th drop One drop equals 100ppb Slightly shake the test bottle every time the reagent is dropped DH test results may vary depending on the environment Use the hydrogen meter for exact results For more exact results do the test after running the cleaning mode Do not reuse the reagent once opened Youmayrefert...

Page 12: ...http www h2cap com ...

Reviews: