wc_tx003614gb_FM10.fm
167
Mobile Generator
General Maintenance
16.8
Checking the Exhaust System
When
Check the exhaust system weekly before operating the machine.
Background
A leaky exhaust system will adversely affect machine operation. Symptoms include
increased noise and visible soot deposits. Leaking exhaust can also ignite
surrounding materials and pipe insulation, causing a fire.
Requirements
■
Engine is stopped
■
Exhaust pipes and muffler are cool to the touch
Procedure
Perform the following procedure to check the exhaust system.
1. Open the access door on the curb side of the machine.
2. Inspect the exhaust pipes
(a)
and muffler
(b),
looking for:
Cracks or holes
Burned or missing insulation
Loose or missing clamps
Black soot deposits, especially around welds and joints
3. Start the engine. Listen carefully for:
Excessive noise
Rumbling
High-pitched whine
Rattling
Repair or replace faulty components before putting the machine back into service.
Result
The exhaust system has now been checked.
wc_gr009917
a
b
a
a
Summary of Contents for G 240
Page 1: ...5000186930 09 0215 5 0 0 0 1 8 6 9 3 0 Operator s Manual Mobile Generator G 230 G 240 EN...
Page 6: ...Foreword 6 wc_tx003565gb_FM10 fm Notes...
Page 178: ...wc_tx003849gb_FM10 fm 178 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770051...
Page 179: ...wc_tx003849gb_FM10 fm 179 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770052...
Page 180: ...wc_tx003849gb_FM10 fm 180 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770048...
Page 184: ...wc_tx003663gb_FM10 fm 184 Engine Maintenance T4i Cummins QSB6 7 770016...
Page 211: ...wc_tx003111gb_FM10 fm 211 User s Information for Transport Canada Fuel Tank...
Page 212: ...wc_tx003111gb_FM10 fm 212 User s Information for Transport Canada Fuel Tank...
Page 252: ......
Page 253: ......