G 100 / G 120
Maintenance
wc_tx000996gb.fm
79
6. If necessary, enter your password. (See
Entering Passwords
for more
information.)
7. When prompted, select YES and press the check mark button.
8. Exit by repeatedly pressing the left arrow button
(4)
until the LCD panel display
returns to monitoring status.
7.4
Replacing the Air Filter Element
Prerequisites
Machine shut down
Yellow indicator of the engine air filter gauge has reached the red line
Background
The air cleaner assembly contains a one-piece single element air filter cartridge
(c)
. This cartridge must be replaced when the yellow indicator of the engine air filter
gauge reaches the red line.
Procedure
Follow the procedure below to replace the primary air filter element.
9. Remove the end cover
(d)
, then discard the entire air filter cartridge
(c).
10.Insert a new air filter cartridge.
11.Re-install the end cover, making sure that the dust cap is clean and pointing
downward.
12.Make sure that the intake piping
(a)
is fully engaged over the neck of the filter to
ensure a good seal.
Maintenance
Periodically, make sure the inlet pipe is free from obstructions.
Check all connections and make sure they are snug. An air leak at the neck
clamp, gauge connection, or intake pipe can quickly lead to engine damage.
If the filter housing, gauge connection, neck, or inlet pipe are crushed or
damaged, replace them immediately.
wc_gr005198
c
a
d
Summary of Contents for G 100
Page 1: ...5000185616 04 0911 5 0 0 0 1 8 5 6 1 6 Operator s Manual Mobile Generator G 100 G 120 EN...
Page 5: ...G 100 G 120 Foreword wc_tx000994gb fm 5...
Page 6: ...Foreword G 100 G 120 6 wc_tx000994gb fm...
Page 10: ...10 wc_bo5000185616_04TOC fm Table of Contents G 100 G 120...
Page 33: ...G 100 G 120 Lifting and Transporting wc_tx001191gb fm 33 Notes...
Page 90: ...Technical Data G 100 G 120 90 wc_td000298gb fm Notes...
Page 91: ...G 100 G 120 Schematics wc_tx000998gb fm 91 10 Schematics This page is intentionally left blank...
Page 96: ......
Page 97: ......