Current Overload Fault
Along with engine functions, the ECM continuously monitors the current load in
each phase. The values for current overload are programmed into the ECM at the
factory and are different for each generator size.
1. When an overcurrent condition is sensed in any leg, the warning/fault LED
(d)
will flash and the display will indicate OVERCURRENT.
2. If the overcurrent condition persists, the main circuit breaker
(a)
will open and
the display will change to OVRLOAD - SET BRKR. This indicates an overload
fault.
3. To clear the overload fault, reset the main circuit breaker. Failing to reset the
main circuit breaker will cause the machine to shut down after 5 minutes. The
display will then change to OVERLOAD.
4.20
Event Log
The control module contains an event log that records the first and last
occurrences of pre-alarms and alarms. See
Using the LCD and Keypad
for
instructions on how to access the event log.
wc_gr008167
A
Ø
HZ
V
R
B
a
s
le
r
DIAGNOSTICS
DIAGNOSEN
DIAGNOSTICOS
DIAGNOSTICS
AUS
AUS
APAGADO
APAGADO
ARRET
ARRET
OFF
OFF
REMOTE START
REMOTE START
FERNSTART
FERNSTART
ARRANQUE REMOTO
ARRANQUE REMOTO
DEMARRAGE A
DEMARRAGE A
DISTANCE
DISTANCE
START / LAUFEN
START / LAUFEN
ARRANQUE / MARCHA
ARRANQUE / MARCHA
DEMARRER / MARCHE
DEMARRER / MARCHE
START / RUN
START / RUN
d
a
Summary of Contents for G 100
Page 1: ...5000185616 04 0911 5 0 0 0 1 8 5 6 1 6 Operator s Manual Mobile Generator G 100 G 120 EN...
Page 5: ...G 100 G 120 Foreword wc_tx000994gb fm 5...
Page 6: ...Foreword G 100 G 120 6 wc_tx000994gb fm...
Page 10: ...10 wc_bo5000185616_04TOC fm Table of Contents G 100 G 120...
Page 33: ...G 100 G 120 Lifting and Transporting wc_tx001191gb fm 33 Notes...
Page 90: ...Technical Data G 100 G 120 90 wc_td000298gb fm Notes...
Page 91: ...G 100 G 120 Schematics wc_tx000998gb fm 91 10 Schematics This page is intentionally left blank...
Page 96: ......
Page 97: ......