T01066GB.fm
17
6
.
Malfunctions
FUE 6/042/200 US
For all machines:
1
Have machine repaired by Wacker Neuson Service, your
Wacker Neuson subsidiary or your Wacker Neuson dealer.
Addresses can be found on the Wacker Neuson homepage.
Malfunction
Cause
Remedy
Vibrators are not
working
* Frequency is too low
* Increase frequency via
frequency controller
FUE does not work
* Both LEDs are not lit
* Red LED in the reset
button is lit
* Frequency converter is
defective
* Current consumption is
too high, overload
* Have machine repaired
1
* Press the reset button,
machine restarts
Malfunction
Cause
Remedy
FUE does not work
None of the LEDs are lit
* CEE plug is plugged in
to the receptacle,
* There is no voltage
present
* Fault current protective
switch in the worksite
switchgear assembly was
triggered
* Inverter module in the
FUE defective
Reset the fault current
protective switch
FUE does not work
None of the LEDs are lit
* Inverter module in the
FUE defective
* Have machine repaired
1
FUE does not work
* Green LED is not lit
* Transformer is too hot
and has switched off
* Allow machine to cool
down in the air
* Only use air as a cooling
medium
FUE is working
White or green or both
LEDs are not lit
LED defective
Replace LED
FUE starts sluggishly
Power demand of the
connected machines is
too high
* Observe the power
specifications on the
rating plate,
* Reduce the number of
machines
Summary of Contents for FUE 5/042/200