Connecting the inverter
4
.1
Assembly
4
.
1
.1
Assembly instructions for the version without plug receptacle
Danger of electrocution!
Only a qualified electrician is permitted to assemble the plug and
perform a safety check.
Observe the assembly instructions!
4
.2
Turning on the inverter
Only for FUE 6/042/200 US:
4
.
2
.
1
Plug the CEE plug into a suitable CEE plug receptacle (230 V, 50/
60 Hz).
∗
The CEE plug receptacle must be fuse protected with a 30 mA fault
current protective switch.
∗
The machine requires 1 phase and a grounded conductor.
For all other machines:
4
.
2
.
2
Plug the CEE plug into a suitable CEE plug receptacle (400 V, 50 Hz).
∗
The CEE plug receptacle must be fuse protected with an all-current
sensitive 30 mA fault current protective switch.
∗
The machine requires 3 phases and a grounded conductor.
4
.
2
.
3
The machine is turned on with the green On button.
∗
The white LED lights up when the inverter is ready for operation.
∗
If the green LED lights up, the temperature of the installed transformer
is OK, and the voltage is output at the plug receptacles (a soft
humming sound can be heard).
Danger to life