10 Troubleshooting
100_0202_ts_0010.fm
58
10.5
Perform jump start with donor starter battery
If the starter battery of the machine is discharged and the engine does not start, a jump-start with a donor
battery is possible.
22
Charge controller/
start error.
Charge controller, starter motor, or
electrical connection is defective.
Have the machine repaired.*
Battery is discharged or defective.
Charge or replace battery.
23
Diesel valve error
Diesel valve is defective.
Machine cannot be switched off.
Have the machine repaired.*
24
Gas adjuster error
Fuel tank is empty.
Top up fuel.
Gas adjuster or electrical connection
is defective.
Cable of the gas adjuster is defective.
80 A fuse has blown.
Have the machine repaired.*
25
Hydraulic
temperature sensor
error
Hydraulic temperature sensor outside of
the valid range.
26
Oil pressure
shutdown
Engine oil level is too low.
1. Deactivate machine.
2. Top up motor oil.
Oil pressure switch or electrical
connection is defective.
Have the machine repaired.*
27
Overload sensor error
Overload sensor or electrical connection
is defective.
28
IR receiver error
Incorrect current value.
29
IR receiver error
No power/not connected.
30
Error center pole unit
No signal/not connected.
-
Decoder error
Electrical connection in the electrical
box is defective.
1. Deactivate machine with
emergency shutdown
switch.
2. Have the machine
repaired.*
*
Have this work done by the service of Wacker Neuson.
WARNING
Risk of explosion from explosive gas.
Risk of injury from splashing acid.
Wear safety glasses and protective gloves.
The donor battery and starter battery of the machine must have the same voltage (12 V)
Avoid short circuit from reverse polarity (plus to plus, minus to minus).
Use correct sequence when connecting the jumper cables.
NOTE
Use only insulated jumper cables with a conductor cross-section of at least 16 mm².
Error code
Display
Possible causes
Remedial measure