![Wacker Neuson Cub 200 Repair Manual Download Page 40](http://html1.mh-extra.com/html/wacker-neuson/cub-200/cub-200_repair-manual_3123718040.webp)
Troubleshooting the Burner
Cub 200/300
40
ghi_tx001207gb.fm
Continued from the previous page.
7. Turn the machine off.
8. Remove the screws
(c)
that hold the control panel and pull the control panel
from the machine.
9. Remove the cover
(d)
from the control.
10.Turn the machine on.
11.Measure the voltage at terminals
M17
and
M16
.
Is 108–132 VAC measured?
This procedure continues on the next page.
WARNING
Electric shock hazard. High voltage exists at the control panel when the machine is
turned on. Electric shock can cause severe injury or death.
f
Use extreme care and appropriate arc flash protective measures when working
inside the machine.
Yes ____
No ____
Continue.
The control board has failed. Disconnect the power supply and
replace the control board.