![Wacker Neuson Cub 200 Repair Manual Download Page 25](http://html1.mh-extra.com/html/wacker-neuson/cub-200/cub-200_repair-manual_3123718025.webp)
Cub 200/300
Burner Setup
ghi_tx001317gb.fm
25
3.7
Checking and Adjusting the Fuel Pressure
Requirements
Pressure gauge
British Parallel Thread (BPT) adapter
Procedure
To check and/or adjust the fuel pressure, carry out the following procedure:
1. Shut down the machine and allow it to cool.
2. Disconnect the power cord from the power source.
3. Open the access panel
(a)
.
4. Remove the threaded plug
(b)
from the pressure test port using an allen
wrench. Set the plug in a safe location to be re-installed later.
5. Install a pressure gauge with BPT adapter
(d)
in the pressure test port.
6. Reconnect the power source.
7. Start the machine
.
With the machine running and access panel closed, observe
the fuel pressure on the gauge
(c)
. For the correct pressure, refer to the
Technical Data
charts in this manual.
8. Shut down the machine.
This procedure continues on the next page.