Manuale d’istruzioni
Instruction handbook
15
9.
PROBLEMS AND SOLUTIONS
After the activation of the general switch of the machine and it doesn’t start:
1. Verify if the switch and the internal contact of the switch.
2. Verify that lowering the platen, the micro switch placed at the inside of the machine will be
pressurised.
3. Control the fuses that are at the inside of the electrical card.
The machine gets the vacuum in the bag but it does not make the welding:
Verify if at the moment of the insertion of the welding through the push-button, there are
flashings to side on the clips. If will be this verification, the cause would be the resistance of
electrical worker.
The platen does not remain closed, also exercising the corrected pressure:
Verify that the gasket put under the platen with handle will be perfectly integrated and will tie
in the inferior platen and that the bag comes place without any anomalies.