- 9 -
TROUBLESHOOTING
Burner does not com e on A. Problem with gas valve. (Call for service).
when the control knob is B. Pilot burner not lit.
turned on C. Low gas pressure. (Call for service)
Too m uch heat
A. Burner valves adjusted too high
B. Fault y ventilation
C. Overrated gas pressure
D. Im properly adjusted burner
Uneven heat side to side
A. Burner valves im properly adjusted
B. Appliance is not level side to side
C. Im properly adjuste d burner
Uneven heat front to back
A. Appliance is not level front to back
B. Fault y ventilation
C. Im properly adjusted burner
Pilot burner will not stay lit
A. Pilot f lam e is set too low . Adjust pilot to allow for ga s flow.
B.Obstruction in pilot orifice
C. Low gas pressure. (Call for Se rvice).
Yellow burner flam es
A. Open burner shutters until flam es are blue
Lifting burner f lam es
A. Close burner shutters until flam es touch burner
Fluctuating gas pressure
A. Check for clogged vent on regulator