SERVICE
SETTINGS
KEY SEQUENCE
DISPLAY
ITEM
DESCRIPTION
5
Temp Offset
Press 5 to change offset temperature.
Press toggle key to change offset value to (+) or (-)
(positive or negative).
Enter the offset value using the number keys on the
keypad.
NOTE:
Offsets the actual oil temp sensed by the
temperature probe during calibration. Enter a positive
number to decrease the actual oil temperature; or a
negative number to increase the oil temperature.
Press PROGRAM Key to save the selection.
OFF
00
F
(always in
°F)
Degrees Fahrenheit and
positive zero are the
defaults.
6. Baskets
Press 6 to change the number of basket lifts.
Press toggle key to select 0, 1, or 2.
Press PROGRAM Key to save the selection.
2
Display shows 0, 1 or 2
7. Diagnostics
Press 7 to enter diagnostic mode (outputs for heat,
basket lifts and cooking timers remain off).
___
DIAGNOSTICS
(shown on display screen)
1.) L Basket
Press 1 to toggle left basket lift output to lower the lift. DOWN
Lowers basket
Press 1 again to raise the lift.
UP
Raises basket
2.) R Basket
Press 2 to toggle right basket lift output to lower the
lift.
DOWN
Lowers basket
Press 2 again to raise the lift.
UP
Raises basket
3.) Heater
Press 3 to turn heat output ON for 3 seconds only.
OIL TEMPERATURE LED's light with heat demand.
On then
OFF
Gas burner or heating
elements turn on then off.
4.) Filter
Press 4 to turn filter output ON.
ON
Pump motor on
NOTE:
Filtering system fryer batteries only
Press 4 again to turn output OFF.
OFF
Pump motor off
5.) Drain
Display indicates the position of the drain valve. (DVI
switch input to control) (keypress not required).
Manually change valve position to test, and display
will update.
CLOSED
Drain valve open
OPEN
Drain valve closed
CLOSED
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - SERVICE PROCEDURES AND ADJUSTMENTS
F45474 (0413)
Page 34 of 55