2.
Unplug temperature probe lead wire connector.
Fig. 15
NOTE:
This picture shows the probes with the burner
removed.
3.
Loosen compression nut and remove probe from
fryer.
Fig. 16
4.
Install new probe making sure that probe is
installed into bracket shown.
HIGH LIMIT THERMOSTAT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
Do not sharply bend or kink the high limit
capillary tube or damage may occur.
1.
Drain shortening from fryer tank.
2.
Disconnect lead wires from high limit thermostat.
3.
Remove screws securing high limit to mounting
bracket.
Fig. 17
4.
Remove the capillary tube retaining and packing
nuts.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - REMOVAL AND REPLACEMENT OF PARTS