Fig. 4
BOTTOM COMPONENTS - WATER
LEVEL PROBE (LLCO), TEMP
SENSOR & PRESSURE SWITCH
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
Open pressure relief valve until reservoir jacket
is completely vented.
2.
3.
Disconnect lead wires from component being
replaced.
4.
If removing pressure switch:
A.
. Disconnect compression fitting from elbow
near the pressure switch.
B.
Remove top nut on brass fitting to remove
pressure switch from mounting bracket.
5.
Remove component from bottom of kettle.
6.
Reverse procedure to install.
7.
Remove air from reservoir jacket as outlined
under VENTING procedure.
8.
Check for proper operation. NOTE:
NOTE:
Pressure switch setting is fixed and should not
be adjusted. Clean threads and apply pipe thread
sealant when replacing pressure switch, water level
probe or temperature sensor.
Fig. 5
POTENTIOMETER
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
2.
Disconnect potentiometer wire from temperature
control.
3.
Pull temperature dial from potentiometer shaft
and remove seal nut.
Electric Countertop Tilting Kettles, K6ETT, K12ETT, K20ETT - REMOVAL AND REPLACEMENT OF PARTS
Page 7 of 28
F35496 Rev. A (1117)