B.
Remove kettle support cover.
Fig. 15
C.
Remove kettle support and bearing housing
assembly from support shaft.
Fig. 16
10. Pull kettle assembly away from control box to
disengage support shaft from inner bearing and
pivot stop collar. Slide kettle onto the 2x4 blocks.
A.
Pull lead wire bundle thru inner bearing and
pivot stop collar during removal.
NOTE:
If support shaft of kettle assembly does not
easily disengage, apply force between control box
housing and kettle assembly to release pivot stop
collar. The support shaft should slide out of inner
bearing easily.
11. If re-installing kettle assembly, proceed to
Installation in this section. If installing a
replacement kettle assembly, remove
components as outlined below from old kettle
assembly for re-use.
A.
Open pressure relief valve until reservoir
jacket is completely vented.
B.
Place kettle on floor with the pressure relief
valve and reservoir jacket fill elbow facing
up.
C.
Remove Table 4.
D.
Remove Water Level Probe.
E.
Position kettle assembly to drain fluid into
container. Remove 1/2" pipe plug from the
reservoir jacket fill elbow to facilitate
draining.
F.
Remove Temperature Sensor & Pressure
Switch including condensate coil.
G. Remove pressure relief valve assembly
plumbing and reservoir jacket fill elbow.
H.
Remove HEATING ELEMENT.
I.
Install all removed components onto
replacement kettle. Clean threads and apply
sealant before re-installing pipe fittings.
Installation
1.
Place kettle assembly on 2x4 blocks and align
support shaft to shaft seal. Pull lead wire bundle
thru shaft seal and inner bearing.
NOTE:
Bearings and shaft seal are self aligning for
easy installation. Bearings do not require lubrication.
Electric Countertop Tilting Kettles, K6ETT, K12ETT, K20ETT - REMOVAL AND REPLACEMENT OF PARTS
F35496 Rev. A (1117)
Page 10 of 28