www.vtiinstruments.com
EX1200-7100 Plug-in Module
151
EX1200-7100
S
PECIFICATIONS
RF
P
ERFORMANCE
S
PECIFICATIONS
Frequency (GHz)
VSWR
Insertion loss (dB max)
Isolation (dB min)
RF power (CW)
DC – 4
4 – 8
8 – 12
12 – 18
18 – 26
1.25:1
1.35:1
1.40:1
1.50:1
1.8:1
0.20
0.30
0.40
0.50
0.80
70
65
60
60
50
100
70
60
45
30
A
DDITIONAL
S
PECIFICATIONS
Maximum operating voltage
Maximum current rating (carrier)
Maximum current per switch
7102/7104/7106
7122
Switching time
Operating mode
7102/7104
7106
7122
Switching sequence
Operating life
24 V dc
1 A
140 mA @ nominal voltage and 25 °C
280 mA @ nominal voltage and 25 °C
20 ms (maximum)
Failsafe
Normally open
Transfer, failsafe
Break-Before-Make
2,000,000 cycles per position minimum