VTI Instruments Corp.
114
EX1200-5004 Plug-in Module
EX1200-5004
S
PECIFICATIONS
G
ENERAL
S
PECIFICATIONS
C
HANNEL
C
OUNT
32 SPDT
M
AXIMUM
S
WITCHING
V
OLTAGE
250 V ac rms, 110 V dc
M
AXIMUM
S
WITCHING
C
URRENT
5 A
M
AXIMUM
S
WITCHING
P
OWER
150 W dc, 1250 VA per channel
18 kW per switch module
M
INIMUM
C
ONTACT
R
ATING
*
10 mA, 5 V dc
*This value is in reference to a resistive load. Minimum capacity changes depending on switching frequency and environmental conditions
R
ATED
S
WITCH
O
PERATIONS
Mechanical
Electrical
1 x 10
7
5 x 10
5
S
WITCHING
T
IME
< 3 ms
P
ATH
R
ESISTANCE
< 0.15 Ω
I
NSULATION
R
ESISTANCE
> 1 x 10
9
Ω
M
AXIMUM
T
HERMAL
O
FFSET
PER
C
HANNEL
(HI-LO)
< 7 μV
C
APACITANCE
Open channel
Channel-mainframe
< 50 pF
< 80 pF
B
ANDWIDTH
(-3
D
B)
50 MHz (typical)
C
ROSSTALK
(T
YPICAL
)
100 kHz
1 MHz
10 MHz
< -80 dB
< -60 dB
< -40 dB
I
SOLATION
(T
YPICAL
)
100 kHz
1 MHz
10 MHz
< -50 dB
< -45 dB
< -40 dB
I
NSERTION
L
OSS
(T
YPICAL
)
100 kHz
1 MHz
10 MHz
< 0.1 dB
< 0.2 dB
< 1.0 dB
For mating connector, crimp pins, and other accessories, please refer to
Appendix B
.
Summary of Contents for EX1200 Series