Configuration File Parameter Guide
193
VSP716A Administrator and Provisioning Manual
Setting:
tone.congestion_tone.element.1
Description:
Defines the dial tone element 1.
Values:
Tone element string
Default:
1 950 -22 0 0 0 0 0 0 330 0 1
Setting:
tone.congestion_tone.element.2
Description:
Defines the dial tone element 2.
Values:
Tone element string
Default:
1 1400 -22 0 0 0 0 0 0 330 0 1
Setting:
tone.congestion_tone.element.3
Description:
Defines the dial tone element 3.
Values:
Tone element string
Default:
1 1800 -22 0 0 0 0 0 0 330 1000 1
Setting:
tone.congestion_tone.element.x
Description:
Defines the dial tone element x (x = 4–5).
Values:
Tone element string
Default:
Blank
Setting:
tone.congestion_tone.num_of_repeat_all
Description:
Sets the number of repeats of all elements in sequence; that is, repeating
back to the first element.
Values:
0–65535
Default:
65535
Setting:
tone.auto_answer_tone.num_of_elements
Description:
Sets the number of tone elements for the auto answer tone.
Values:
1–5
Default:
1
Setting:
tone.auto_answer_tone.element.1
Description:
Defines the dial tone element 1.
Values:
Tone element string
Default:
2 500 -22 800 -22 0 0 0 0 1000 0 1
Setting:
tone.auto_answer_tone.element.x
Description:
Defines the dial tone element x (x = 2–5).
Values:
Tone element string
Default:
Blank