Configuration File Parameter Guide
126
VSP716A Administrator and Provisioning Manual
All these settings are exported when you manually export the configuration from the
VSP716A.
General configuration file settings
Setting:
sip_account.x.dial_plan
Description:
Sets the dial plan for account x. See
.
Values:
Text string
Default:
x+(#:)|x+P
Setting:
sip_account.x.emergency_dial_plan
Description:
Sets the emergency dial plan.
Values:
Text string
Default:
blank
Setting:
sip_account.x.inter_digit_timeout
Description:
Sets the inter-digit timeout (in seconds) for account x. The inter-digit
timeout sets how long the VSP716A waits after the last digit is entered
before dialling the number.
Values:
1–10
Default:
3
Setting:
sip_account.x.maximum_call_number
Description:
Sets the maximum number of concurrent active calls allowed for that
account.
Values:
1–
Default:
Setting:
sip_account.x.auto_answer_enable
Description:
Enables or disables automatic answering of pages for account x.
Values:
0 (disabled), 1 (enabled)
Default:
0
Setting:
sip_account.x.auto_answer_during_active_call
Description:
Enables or disables automatic answering of pages for account x when
account x has an active call.
Values:
0 (disabled), 1 (enabled)
Default:
0