background image

1.2 Product Description 

 
The VST Fuel S-810  Fuel Management System is a self- contained, micro-processor based, control and data 

acquisition system designed to authorize, monitor, and record fuel dispensing operations.  The VST Fuel 
S-810 consists of an Island Mounted Data Entry Terminal (DET) which has the capability of simultaneous 
control and monitoring of from one to four dispensers.  Access input device options for the VST Fuel S-810 
are available for magnetic cards, optical cards, touch buttons, or keys.  Models are also available which use 
keypad entry only and do not require an input device. 

 
Operating the VST Fuel S-810 is straightforward.  The user inserts his input device or “keypad entry only” into the 

VST Fuel S-810 and enters the required information on the keypad; usually a PIN number and odometer 
reading, etc..  If the input device and the entered information are valid, the VST Fuel S-810 applies power 
to the requested pump, allowing the user to dispense fuel.  At the completion of fueling, the VST Fuel 
S-810 transmits transaction information to its output devices and stores the information in its transaction 
memory for later recall. The VST Fuel S-810 will hold up to 1000 transactions in memory for 
downloading. 

 
The VST Fuel S-810 Fuel Management System has the capability of operating with a wide range of output devices, 

which include printers, modems, personal computers, and other devices which are RS-232 or RS-485 
compatible. 

 
The various system operations for control of the VST Fuel S-810 and the generation of reports from the VST Fuel 

S-810 are thru priority VST Fuel Management, Inc. software.  These commands may be issued locally from 
a personal computer or remotely by dial-up communications from a personal computer, , or other serial 
communication device. Refer to the Operators Manuals and Reference Manuals for additional information. 

 

 

1.3 Specifications 

 

Power Requirements:

115 VAC,  50/60 HZ,  1/2 A or 
 

Dimensions:

15.5 inches wide x 10.5 inches high x 13.5 inches deep 

Weight:

Approximately 25 Pounds  

 

Operating Temperature:

-30 to 140 Degrees Fahrenheit 

 

Environment :

Weatherproof, suitable for outdoor mounting in a  
non-classified area in a service station.  Not suitable   
for direct connection to intrinsically safe wiring. 

 

Pump Controls/Monitors:

1 Control Relay:

115 VAC, 6 A, 1/3 HP or 

(Per pump, four pumps max.)

230 VAC, 3 A, 1/3 HP 

1 Pulser Input:

12 VDC, 10 ma Minimum, 
50% duty cycle, pulse rates 
up to 500 pulses per minute 

1 Handle Switch Input:

115 VAC, 20 MA Maximum or 
230 VAC, 20 MA Maximum 

 

Communications:

3 RS-232/RS-485 Asynchronous Communication Ports 
  

 

 

 VST, 2010

 

 

Summary of Contents for S-810

Page 1: ...ent contains information proprietary to VST Fuel Management Inc and shall not be disclosed duplicated or used for procurement design or manufacture without the expressed written consent of VST Fuel Ma...

Page 2: ...y precaution to prevent possible hazards which could result in serious bodily injury and property damage You are responsible for installing this product according to the instructions and warnings cont...

Page 3: ...rements 9 4 2 Wire Manufacturers 9 4 3 Dispensers Pumps 9 Table 1 Size of Dispenser Junction Box 10 b Interface wiring 11 c Dispenser wiring 11 Figure 4 Typical Wiring for 115Vac or 230 Vac VST Fuel S...

Page 4: ...on This manual provides a general description of various types of installations applicable to VST Fuel S 810 systems Installation shall be in accordance with National Electric Code NFPA 70 the Automot...

Page 5: ...Figure 1 Typical Installation of VST Fuel S 810 VST 2010 5...

Page 6: ...nsactions in memory for downloading The VST Fuel S 810 Fuel Management System has the capability of operating with a wide range of output devices which include printers modems personal computers and o...

Page 7: ...ry representative 2 2 Parts Verification Prior to starting work make sure that all of the correct parts have been received You will also need the following partial list of parts to complete the instal...

Page 8: ...d using either of two methods The first method is mounting the DET on the top of a 2 inch pipe x 55 approx height The DET is simply screwed onto the pipe and after being positioned for operation the t...

Page 9: ...Figure 2 VST Fuel S 810 Dimensions VST 2010 9...

Page 10: ...Figure 3 VST Fuel S 810 Pedestal Mounting VST 2010 10...

Page 11: ...end only AC wire size is to be minimum AWG 14 All wiring should be either color coded or numbered to facilitate connection of the wire ends CAUTION Do not use non moisture non oil proof or standard h...

Page 12: ...WARNING IN INSTALLATION AND USE OF THIS PRODUCT COMPLY WITH THE NATIONAL ELECTRICAL CODE FEDERAL STATE AND LOCAL CODES AND ANY OTHER APPLICABLE SAFETY CODES IN ADDITION TURN OFF POWER AND TAKE OTHER...

Page 13: ...rical Code to determine size of conduit required for the number of conductors b When possible install at least 25 percent spares for expansion and maintenance CAUTION NEVER RUN AC OR OTHER EQUIPMENT W...

Page 14: ...control This control may be implemented through the use of electrically operated solenoid valves 5 Pulser Wiring Each dispenser pump or hose to be controlled and monitored by the VST Fuel S 810 syste...

Page 15: ...signals CTS DCD RTS and DTR may be connected on a one for one basis if desired See Figure 13 The support of these signals is limited to providing the correct signal level for operation of the modem W...

Page 16: ...trol the correct pump When Diagnostic four is selected the display will change to the following SELECT PUMP When you press key 1 the display will change to the following 1 2 3 4 PUMPS The four pumps 1...

Page 17: ...l 810 power switch to the on position Put the VST Fuel S 810 into the keypad diagnostic mode as explained in the previous section Run the diagnostics for the display DIAG 1 and keypad entry DIAG 2 at...

Page 18: ...o the user at the location where the product is in use After the first ninety 90 days of the warranty period VST will repair or replace the product only if it is returned to the VST factory at the Tem...

Page 19: ...Fuel Management Inc in writing of any claims including claims of breach of warranty within thirty days after the facts upon which the claim is based are discovered or should have been discovered Fail...

Reviews: