FLOW-meter Version: 1.0
Page 8/29
Global parameters
general
Pulses/1000ml
Parameter for adapting the FLOW-meter electronics to the respective flow sensor (s.
section 2.0.3 Calibration).
FUEL Tank Size
Volume off the main tank in ml.
FUEL display
Here you can choose whether FUEL should display the increasing fuel consumption
(consumed) or the falling tank content (level).
FUEL rounded
The display accuracy of FUEL (ml) can be set here.
Rounding the display makes sense, when using speech to reduce the announcement
syllables.
Auto Reset
With Auto Reset = Power ON, the consumption / tank display is reset to 0 ml (FUEL
display = consumed) or FUEL Tank Size (FUEL display = level) each time the
receiving system is switched on.
With Auto Reset = OFF the last value is stored and is available again after the
receiver is switched on again until a reset at the servo input (> 80%).
alarms
FUEL Reserve
Alarm when the value falls below the value set here.
(OFF ... no alarm)
Flow MIN
The FlowMIN alarm is signaled when the current fuel flow set under FlowMIN is
undershot.
This alarm can therefore be used to detect turbine OFF.
The turbine OFF monitoring is started after the value set in FlowMIN has been
exceeded for the first time.
(OFF ... no alarm)