FLOW-meter Version: 1.0
Page 11/29
2.1.2.2
Alarms / Parameterization
From the data display, the parameter display can be accessed by pressing the
Down button.
With the
Up button the parameter display will left.
Within the parameter display you can scroll with the
Right button - or -
Left button
between the parameter groups "FUEL Tank Size", "Pulses/1000ml", "FUEL display",
"FUEL rounded" , "Auto Reset" , "Alarm" , "Alarmcode" und "FLOW-meter-EX-Name".
When the desired parameter group is selected, the parameter can be changed by using
Down and
Up button.
Value changes are made with the
Right button – or-
L
eft button.
Example of parameter selection and parameterization:
Down-Button
Right-Button
Down-Button
Right-Button (multiple times)
Up-Button
Up-Button
Parameter-
group
Parameter
Value range
Step size
Set-Value
(Default)
FUEL Tank Size
200
. . . 20.000 ml
50 ml
3000 ml
Pulses/1000ml
50
. . . 20.000
10
(calibr. value)
FUEL display
consumed / level
consumed
FUEL rounded
1, 5, 10, 20, 50, 100
10
Auto Reset
Power ON / OFF
Power ON
Alarm
Reserve
OFF, 50
. . . 2.500 ml
10 ml
OFF
FlowMIN
OFF, 10
. . . 500 ml/min
10 ml/min
OFF
Alarmcode
Reserve
A, B, C, . . . , X, Y, Z
C
FlowMIN
V
Flowmeter
EX Name
VSFLOW, L-FLOW, R-FLOW, 1LFLOW,
2RFLOW
VSFLOW