FLOW-meter Version: 1.0
Page 14/29
2.2
Multiplex MLink (MSB)
2.2.1
Address-Assignment / Alarms
The FLOW-meter at delivery uses following addresses:
FLOW-meter
address
Description
FUEL ml
OFF
Cosumption / Tank level in ml
FUEL %
Alarm
11
Cosumption / Tank level in %
FLOW
Alarm
12
current
fuel flow in ml/min
Flow MAX
13
maximum fuel flow in ml/min
For the values indicated in the above table with "Alarm", alarm thresholds can be set with the
aid of a Micro SD card and the parameter file "FLOW.TXT". Furthermore, the MSB addresses
can be set as desired - a double address assignment within the FLOW-meter is excluded
2.2.2
Parameter "FLOW.TXT"
(excerpt section 2.0.2)
=================================================
********** settings Vspeak FLOW-meter **********
=================================================
set value|value range |unit |description
=================================================
general
-------------------------------------------------
5000 |50...20000 | |Pulses/1000ml
3000 |200...20000 |ml |FUEL Tank Size
consumed |consumed, level | |FUEL display
10 |1,5,10,20,50,100 | |FUEL rounded
Power ON |Power ON, OFF | |Auto Reset
alarms
-------------------------------------------------
OFF |OFF,50...2500 |ml |FUEL Reserve
OFF |OFF,10...500 |ml/min |Flow MIN
Multiplex Mlink MSB address
-------------------------------------------------
OFF |OFF,0...15 | |FUEL ml
11 |OFF,0...15 | |FUEL %
12 |OFF,0...15 | |FLOW
13 |OFF,0...15 | |Flow MAX