o Vmax), the - + button must be pressed until the
desired option is displayed.
DISPLAY button
(fig.25)
During the normal operation of the appliance
on
switching the appliance on, the remote control display
will show the following information:
time
day
operation mode: (AUTO, MAN, SUMMER)
operation speed ((Min,Max,Mid (the latter only in the
MAN mode))
The DISPLAY button enables the following system
parameters to be displayed in sequence (by pressing
the button repeatedly for at least 0.5 sec):
Actual Temperature Display (fig.25a)
during
normal
operation,
as
detected
by
the
temperature sensor placed in the home air inlet shaft,
ahead of the heat exchanger
Current humidity display (fig.25b)
not settable by the user (detected by the humidity
sensor placed in the home air inlet shaft, before the heat
exchanger)
CO2 percentage display (fig.25c)
not settable by the user (detected by the CO2 sensor
placed in the home air inlet shaft, before the heat
exchanger).
Residual operating time at Vmax ,(fig.25d)
depending on preset Timer duration (see TIMER button)
Other information displayed automatically, depending
on the conditions:
Excess CO2 threshold warning (see “Warning/error
signals")
Value set during initial configuration of Min and Max
Speed (values from 00 to 99: only during the installer set
up stage)
Clockface symbol: if the Timer function is set (see
25d
25d
17
O
25c
25c
470
CO2(ppm)
25b
25b
23
RH(%)
25a
25a
21
T(°C)
25
25
SET NEXT ENTER
DISPLAY
TIMER
MODE
14:38