Vminsetting (fig. 43):
• to display the setting, press
SET
,
NEXT
(starting from
the main menu);
• to set the value of the flashing field with the
+
and
-
keys (from 0 to 60); press
ENTER
or
NEXT
to confirm.
The display will switch to the Vmax setting.
Vmaxsetting (fig. 44):
• to display the setting, press:
SET
,
NEXT
(starting from
the main menu);
• to set the value of the flashing field with the
+
and
-
keys (from Vmax+10 to 99); press
ENTER
or
NEXT
to
confirm. The display will switch to the main screen.
5) When you have finished making the settings, turn the
remote control unit OFF (the motors will also stop) and
remove the connection with the external radio
module.
6) Disconnect the power supply to the appliance. When
restarted, the system will operate using the configured
settings. the trimmer reading will be ignored.
N.B.
After a certain period of inactivity (about 5 secs) the
remote control unit goes into “stand-by” mode; pressing
any key for a few seconds will reactivate the unit.
Manually making settings using the dip-switch
1) Before connecting the appliance to the mains,
configure the dip-switch using the following method:
(fig. 45).
2) Position both the trimmers fully to the left so that they
can be turned clockwise (fig. 46).
ATTENTION: do not apply excessive force to the
trimmers
3) Connect the appliance to the mains and the
appliance will start at 500 Rpm speed.
4) Set the switch for selecting speed in the position
matching the lowest setting Vmin
ENGLISH
43
SL03
30
44
SH50
45
46
Summary of Contents for VORT HR 200
Page 27: ...clean the heat exchanger re t the heat exchanger gs 34 35 36 ENGLISH 31 32 33 27 34 35 36...