1) Before connecting the appliance to the mains,
connect the external radio module to the electronic
circuit board and configure the dip-switch as shown
(figure 40).
I
n this way, the system will be able to recognise the
settings made using the remote control unit even when
it is no longer connected to the external radio module (in
effect, in this case ignoring the trimmer reading).
2) When the appliance is connected to the power supply,
the system recognises the external radio module and
keeps the motors in the OFF state.
3) Turn ON the (RF) remote control unit (fig. 41) and
check
the
system
status
(brushless
motor
diagnostics, assessment of temperature sensor
reading). Subsequently, the system - unless a fault is
indicated - will start the motors at Vmin and Vmax by
default.
ON/OFF key
(fig. 41)
To turn the appliance ON and OFF. The command is only
carried out if the key is kept pressed for at least half a
second.
4) Setting the required motor speed using the remote
control unit (fig. 42).
SET key
(fig. 42)
For setting the minimum (Vmin) and maximum (Vmax)
speeds. To move from one parameter to the next, use
the
NEXT key.