Description and use
The product you have purchased is a reversible cei-
ling agitator fan unit with a maximum operating tem-
perature of 45°C.
NORDIK ECO series units have
been designed for household
use.
NORDIK ECO series units have been designed for
household installation and use. They are also suitable
for installations in Commercial or Industrial areas pro-
vided environmental conditions are not particularly
aggressive (i.e. corrosive, dusty environments, etc.).
Tools needed for assembly
Figure A
Supplied accessories
Figure B
Installation
Figures: 4 ÷ 50
Please follow the instructions below for installation.
1. Make sure that the ceiling where the unit is to be
installed is structurally sound to support the weight
of the product.
2. Be careful that the anchoring devices do not com-
promise the structural resistance of the ceiling
where the unit is to be installed.
3. Use dowels that can ensure material stays gripped
to the ceiling where the unit is to be installed.
Operation
Caution!!!
The information described in this chapter
only relates to use of the
VORTICE Code 12829
POT-R
regulator. Operation is possible with other
potentiometers provided they have the following cha-
racteristics:
1 - Resistive value 10kOhm
2 - Integrated or external switch
Fans are turned on by means of a switch integrated
into the potentiometer. Start from the stand-by posi-
tion on the knob and turn it clockwise. You will hear
a click when the switch closes and then, when the fan
is switched back on, you will hear a brief buzzer tone
accompanied by a quick ignition of the LED.
The speed setting is continuous. The first half of the
potentiometer full scale is dedicated to adjusting pro-
duct speed in "standard" ventilation (air pushed
toward the floor). The second half of the full scale is
dedicated to "reverse" mode adjustment (air pushed
toward the ceiling). Fan passage from "standard"
ventilation to "reverse" ventilation is highlighted by
two short buzzer tones and two quick ignitions of the
LED, while passage from "reverse" ventilation to
"standard" ventilation is highlighted by a brief buzzer
tone and a quick ignition of the LED (fig.51).
A transition zone (HYSTERESYS ZONE) is indicated
on the potentiometer (fig.52), corresponding to pas-
sage from "standard" ventilation mode operation (at
maximum speed) to "reverse" ventilation mode ope-
ration (minimum speed).
Shut-down occurs by completely rotating the knob in
the counter-clockwise direction. A long buzzer tone
and a long LED ignition will indicate shut-down.
The product can be remotely operated by means of
the
VORTICE Code 21200 TELENORDIK ECO
remote control
Cleaning
Figures: 53 ÷ 56.
Before performing any cleaning or maintenance ope-
rations, turn the unit switch off and disconnect its
plug from the power supply.
Electrical connections
Figures: 57 ÷ 58
Dismantling caps
Figures: 59 ÷ 62 (rods 290÷915)
Figures: 63 ÷ 68 (rod 160)
ENGLISH
Summary of Contents for NORDIK ECO Series
Page 13: ...13 C 90 110 5 5 10 5 NO NO OK OK 90 90 NO 2 3 m 2 3 m 1 2 A Kg 10 Kg40 MAX 3...
Page 14: ...14 5 45 45 4...
Page 15: ...15 7 6...
Page 16: ...16 8 9 90 90...
Page 19: ...19 15 14 2 1...
Page 22: ...22 21 2 CLICK 3 1 1 20...
Page 25: ...25 24 25 26 1 2 3 35...
Page 27: ...27 29 1 2 30...
Page 30: ...30 34 1 2 3...
Page 32: ...32 37 38 1 2 3...
Page 33: ...33 39 1 2 40...
Page 34: ...34 41 42 1 2...
Page 35: ...35 43 CLICK 1 2...
Page 36: ...45 90 36 44 1 2...
Page 37: ...37 46 47 1 2...
Page 38: ...38 49 48...
Page 39: ...39 50...
Page 40: ...40 51 MIN VENT MAX VENT MIN REVERSE MAX REVERSE OFF 52 HYSTERESIS ZONE...
Page 41: ...41 53 54 55 56...
Page 44: ...44 61 62...
Page 46: ...46 65...
Page 47: ...47 66 67...
Page 49: ...49...