38
MANUFACTURER’S PLACEMENT INSTRUCTIONS
PROPER ASSEMBLY, INSTALLATION, USE, AND SUPERVISION IS ESSENTIAL FOR PROPER
OPERATION AND TO REDUCE THE RISK OF SERIOUS INJURY OR DEATH.
1. The critical dimensions for placement of the VORTEX are as shown in FIGURE ’S 33 and 34.
A. The slide exit runway surface shall not exceed twenty inches (20”) above the water surface as
shown in FIGURE 33.
B. The slide shall be positioned so that all water flowing off the runway exit drops into the pool. The
recommended overhang is 4 inches.
C. The minimum depth of water below the exit lip of the slide shall be three feet (3’) and increase to
four feet six inches (4’-6”) at Pt. A, which is a distance of four feet six inches (4’-6”) from the exit
lip of the slide as shown in FIGURE 33.
D. A minimum depth of four feet six inches (4’-6”) shall be maintained at a distance of nine feet (9’)
along the extended centerline of the slide from Pt. A. as shown in FIGURE 33.
2. A minimum clearance area in front of the slide shall be maintained at all times
as follows:
A. The minimum clearance distance on either side of the extended
centerline of the slide runway shall not be less than three feet six inches
(3’-6”) at a point no less than two feet six inches (2’-6”) from the exit lip of
the slide and extending a distance of thirteen feet six inches (13’-6”) in
front of the slide as shown in FIGURE 34.
FIGURE 33
FIGURE 34