Preparation of tests

•  The device is switched on by pressing on/off switch (5).
•  The beeper, red LED (3) and vibration motor switch on briefly for self-testing.
•  The test area from 50 V to 1000 V is set after switching on. Brief pressing of the on/off switch 

(5) sets the sensitivity range from 12 V to 50 V. Voltages from 50 V to 1000 V are also indi-

cated in the range from 12 V to 50 V . If a source of voltage above 50 V is in the vicinity of a 

12 V voltage source, the tester will detect the more powerful one.

•  The flashing red LED demonstrates readiness.
•  The tester is switched off by pressing the on/off switch (5) for 1 second.
•  The tester turns off automatically after approx. 3 minutes.

Performing tests

a)  Voltage test

•  Move the device slowly along the tested object e.g. a cable.
•  If the device detects alternative voltage in the 12...50 V mode, the red LED flashes, the motor 

vibrates and the tone generator produces a sound signal.

•  If the device detects alternative voltage in the 50...1000 V mode, the red LED glows continu-

ously, the motor vibrates and the tone generator produces a sound signal.

•  Testing may be influenced by the position of the ground wire in the tested object.

b)  Magnetic field tests

•  Move the device slowly along the tested object.
•  If the device detects a magnetic field, the yellow LED lights up.

c)  Torch

•  Press the „torch“ button (6) to switch on the torch.

Cleaning

Prior to cleaning the device, switch the product off.

  Live components may be exposed if the covers are opened or parts removed 

(unless this can be done without tools).

•  Do not use scouring, chemical or aggressive cleaning agents such as benzene, alcohol or 

such like. These might attack the surface of the device. Furthermore, the fumes are explosive 

and hazardous to your health. Moreover, you should not use sharp-edged tools, screwdriv-

ers, metal brushes or similar implements for cleaning.

•  To clean the device, use a clean, slightly damp, fuzz-free, antistatic cleaning cloth.

Disposal

a)  Product

 Electronic devices are recyclable material and do not belong in the household waste.

 

Dispose of an unserviceable product in accordance with the relevant statutory regu-

lations.

 

Remove any inserted batteries/rechargeable batteries and dispose of them sepa-

rately from the product.

b)  Battery

As the end user, you are required by law (Regulation on Spent Batteries) to return all dead 

batteries and accumulators. Disposal in the household waste is prohibited.

  Batteries/rechargeable batteries contain harmful materials and are labelled with the 

symbol shown to indicate that disposal in the household waste is forbidden. The 

symbols of the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (the 

marking can be seen on the battery/rechargeable battery, e.g. underneath the re-

fuse bin symbol shown on the left).

You can return your used batteries/rechargeable batteries free of charge at the official col-

lection points of your community, in our stores, or at places where batteries or rechargeable 

batteries are sold.

Technical data

Indicator ....................................................... LED
Sound generator  ......................................... yes
Vibration ...................................................... yes
Voltage range .............................................. 12 V to 1000 V/AC (2 measuring ranges)
Frequency range ......................................... 50 bis 400 Hz
Magnetic field .............................................. AC, DC (also permanent magnets)
Operating voltage ........................................ 2x 1.5 V micro batteries (type AAA) 
Current consumption ................................... approx. 80 mA
Protection class ........................................... 2 (double or reinforced insulation)
Type of protection ........................................ IP64
Operating temperature range ...................... -10 °C to +55 °C
Storage temperature .................................... -20 °C to +65 °C
Relative humidity ......................................... 85% relative (non-condensing)
Dimensions .................................................. 155 x 25 x 23 mm (L x W x H)  
Weight ......................................................... 55 g

Summary of Contents for MS-450

Page 1: ...er Tester arbeitet berührungsfrei sodass die Gehäuse meist nicht geöffnet werden müssen Wird ein Magnetfeld erkannt be ginnt die Prüfspitze gelb zu leuchten Wird ein magnetisches Gleich und Wechselfeld erkannt beginnt die Prüfspitze je nach Messbereich rot zu leuchten oder schnell zu blinken das Gerät vibriert und ein Signalton erklingt Zusätzlich ist im Tester eine LED Lampe eingebaut Der Magnetf...

Page 2: ...lampe Taste 6 ein Reinigung Bevor Sie das Gerät reinigen schalten Sie es aus Beim Öffnen von Abdeckungen oder Entfernen von Teilen außer wenn dies von Hand möglich ist können spannungsführende Teile freigelegt werden Verwenden Sie zur Reinigung keine scheuernden chemischen oder aggressive Reinigungs mittel wie Benzine Alkohole oder ähnliches Dadurch wird die Oberfläche des Gerätes ange griffen Auß...

Page 3: ...tc The tester works with any contacts and therefore it is normally not necessary to open the casing When a magnetic field is detected the test tip starts to flash yellow If a constant and alternating magnetic field is detected the probe starts glowing red or flashing rapidly depending on the measuring range the device starts vibrating and a sound alert can be heard Additionally the tester has an i...

Page 4: ...the product off Live components may be exposed if the covers are opened or parts removed unless this can be done without tools Do not use scouring chemical or aggressive cleaning agents such as benzene alcohol or such like These might attack the surface of the device Furthermore the fumes are explosive and hazardous to your health Moreover you should not use sharp edged tools screwdriv ers metal b...

Page 5: ... dans des relais des électrovannes etc Le testeur fonctionne sans contact il n est donc pas nécessaire dans la plupart des cas d ouvrir le boîtier Quand un champ magnétique est détecté la pointe d essai s allume jaune Si un champs ma gnétique continu et alternatif est détecté selon la plage de mesure la pointe de test s allume en rouge ou clignote rapidement l appareil vibre et un signal sonore re...

Page 6: ...èces risquent de mettre à nu des pièces sous tension sauf lorsqu il est possible d effectuer ces procédures à la main N utilisez jamais de produits de nettoyage abrasifs chimiques ou agressifs tels que des es sences alcools ou autres produits analogues Ils pourraient attaquer la surface de l appareil De plus les vapeurs émises par ces produits sont explosives et nocives pour la santé Pour le netto...

Page 7: ...tvrij zodat de behuizing meestal niet geopend dient te worden Wanneer een magneetveld wordt herkend gaat de testpunt geel oplichten Wanneer een magnetische gelijk en wisselveld wordt gede tecteerd begint de testpunt afhankelijk van het meetbereik rood te op te lichten of sneller te knipperen het apparaat vibreert en een signaaltoon weerklinkt Tevens is in de tester een LED lamp ingebouwd De magnee...

Page 8: ...choonmaken Schakel het apparaat uit voordat u het schoonmaakt Bij het openen van afdekplaten of het verwijderen van onderdelen ook als dit handmatig mogelijk is kunnen spanningvoerende delen worden blootgelegd Gebruik voor het schoonmaken geen schurende chemische of agressieve schoonmaakmid delen zoals benzine alcohol e d Dit tast het oppervlak van het apparaat aan Bovendien zijn de dampen schadel...

Reviews: