Record Start
Condition
“CIRCULAR LOGGING”: Data logger starts
recording immediately and circularly. The
newest data overwrites the oldest data. It
stops recording/logging once the battery is
depleted or “CIRCULAR LOGGING” has
been replaced by another “RECORD START
CONDITION” during configuration.
Stop Style
Select one of the following options to deter-
mine when data logger ends recording.
“NONE”: No stop condition is spe
cified. Data
logger stops recording based on the “RE-
CORD START CONDITION” setting.
“STOP BUTTON”: Data logger stops record-
ing after holding button
ENTER
(8) pressed
for few seconds.
“AFTER PDF CREATED”: Data logger stops
recording after PDF report is generated.
Start Time
Define date and time when to start record
-
ing data.
Stop Time
Define date and time when to stop record
-
ing data.
Start Delay
Minutes
Define delay time of immediate start of re
-
cording.
88