•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these 

may damage the casing or cause the product to malfunction.

Disposal

a) Product

  Electronic devices are recyclable waste and must not be placed in household waste. 

At the end of its service life, dispose of the product according to the relevant statu-

tory regulations.

 

Remove any inserted batteries and dispose of them separately from the product.

b) Batteries

  You are required by law to return all used batteries (Battery Directive). They must not 

be placed in household waste.

 

Batteries that contain hazardous substances are labelled with this symbol to indicate 

that disposal in domestic waste is forbidden. The abbreviations for heavy metals in 

batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (indicated on the battery, 

e.g. below the waste icon on the left).

Used batteries can be returned free of charge to local collection points, our stores or battery 

retailers.

You thus fulfil your statutory obligations and contribute to environmental protection.

Technical data

Power supply ................................ 4 x 1.5 V AAA batteries
Operating current .......................... 5 mA
Standby ........................................ 5 µA
Battery life ..................................... Approx. 120 hours
Low battery level indicator ............ At 4 V residual voltage

pH measurements

Measurement range .....................  -2 to +16 pH
Accuracy ....................................... ±0.01 + 1 digit
Resolution ..................................... 0.01 pH
Correction range ...........................  ATC: 0 to +90 °C

Redox potential measurement

Measurement range .....................  -1000 to +1000 mV
Accuracy ....................................... ±2 + 1 digit
Resolution ..................................... 1 mV

Temperature measurement

Measurement range .....................  0 to +90 °C
Accuracy ....................................... ±0.2 °C + 1 digit
Resolution ..................................... 0.1 °C
Temperature correction ................. Automatic (ATC)
Protection rating ........................... IP57
Operating/storage conditions ........  0 to +50 ºC, <85 % 

relative humidity (non-condensing)

Dimensions (L x W x H) ................  195 x 40 x 36 mm (meter) 

230 x 205 x 50 mm (storage case)

Weight ..........................................  150 g (meter with batteries) 

700 g (complete product)

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in elec

-

tronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is prohibited. 

This publication reflects the technical status at the time of printing.

Copyright 2019 by Conrad Electronic SE.  

*1763396_v1_0919_02_DS_m_4L_(1)

Summary of Contents for 1763396

Page 1: ...es ph Werts Redox Potentials ORP sowie der Tempe ratur unter Verwendung wechselbarer Mess Sonden in Wasser und w ssrigen Medien aus gelegt Anwendungsbeispiele hierf r sind z B Trinkwasser Abwasser Obe...

Page 2: ...rt nur die Werte der letzten 2 Kalibrierungspunkte 7 und 4 oder 7 und 10 Die Steilheit der Elektrode wird dementsprechend nur aus diesen zwei Werten berechnet 14 Nach der Kalibrierung mit pH 4 oder pH...

Page 3: ...n Hausm ll ist untersagt Schadstoffhaltige Batterien sind mit dem nebenstehenden Symbol gekennzeichnet das auf das Verbot der Entsorgung ber den Hausm ll hinweist Die Bezeichnun gen f r das ausschlagg...

Page 4: ...use This product is designed to measure the pH value redox potential ORP and temperature of water and aqueous solutions using replaceable measuring probes Typical applications include drinking water...

Page 5: ...ensures precise measurements when there are different liquid temperatures Measuring the pH value 1 Rinse the probe tip 11 with clean water and wipe it dry 2 Press the button 4 to switch on the meter 3...

Page 6: ...Technical data Power supply 4 x 1 5 V AAA batteries Operating current 5 mA Standby 5 A Battery life Approx 120 hours Low battery level indicator At 4 V residual voltage pH measurements Measurement ran...

Page 7: ...Les exemples d applications de ce produit incluent eau potable eaux us es eaux superficielles piscines pisciculture et processus chimiques La valeur du pH vous renseigne sur la teneur en ions hydrog n...

Page 8: ...choue le symbole SA ne s affiche pas 13 Pour d terminer la pente du c t des bases lorsque voulez mesurer une solution basique vous pouvez galement utiliser la solution tampon avec la valeur de pH 10 p...

Page 9: ...ez les s par ment du produit b Piles Le consommateur final est l galement tenu de recycler toutes les piles ordonnance relative l limination des piles usag es il est interdit de les jeter avec les ord...

Page 10: ...ORP en de temperatuur met gebruik verwisselbare meetsondes in water en waterachtige stoffen Toepassingsvoorbe elden zijn bijvoorbeeld metingen bij drinkwater afvalwater oppervlaktewater in een zwembad...

Page 11: ...nder 70 of meer dan 130 ligt dan moet de meetsonde door een nieuwe worden vervangen Een waarde van 100 is echter ideaal Lees voor meer informatie over en stappen voor het vervangen van de meetsonde de...

Page 12: ...en afgevoerd De aanduidingen voor irriterend werkende zware metalen zijn Cd cadmium Hg kwik Pb lood de aanduiding staat op de batterijen bijv onder de links afgebeelde vuilnisbaksym bool U kunt verbru...

Reviews: