41.VW.2210.3102_BA_V00_EN
VAS 681 003A
42
EN | Operation
Troubleshooting
The DC high-voltage charger outputs the following types of message on the LC display:
•
Warning messages: These messages, if disregarded, will cause the product to lock, which
can then only be reset by the manufacturer. Always carry out the instructions in the
warning messages immediately or contact the manufacturer (see the “Warning
messages” section).
•
Fault messages: In most cases, these messages indicate that a limit value has been
exceeded. Remedy the cause of the fault message according to the instructions below
(see the “Fault messages” section).
DANGER
Danger of fatal electric shock!
Defective and damaged products can no longer guarantee protection against electrical
voltage!
The electrical voltage in the product is lethal and will cause death by electric shock!
•
Switch off the circuit breakers for all the connected sockets before you disconnect the
product from the power supply!
•
Replace a defective or damaged product immediately!
•
Never attempt to repair or tamper with the product!
Warning messages
The table below provides information about the steps you must take to resolve the cause of
these warning messages. Always carry out the instructions in the warning messages
immediately or contact the manufacturer.
Message
Meaning
Corrective action
Service CCS plug
The CCS charging
plug has reached the
maximum number of
mating cycles
The CCS charging plug is a wearing part and
must be replaced after 15,000 mating
cycles.
When this message first appears, the CCS
charging plug still has a maximum of 100
mating cycles left.
The high-voltage DC charger locks when the
CCS charging plug reaches the maximum
number of mating cycles.
Contact the manufacturer before reaching
the maximum number of mating cycles!
An insulation fault
was detected in the
connection to the
vehicle.
By the operator or a high voltage specialist:
•
Inspect the vehicle.
•
Perform vehicle diagnostics.