01-319
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item
tested
Test conditions
- Additional operations
Specification
Measures for
deviations from
specification
19
-
Wiring for
sender 1
for brake
booster -
G201-
Ignition switched off
Measuring range set
to 200
- Disconnect connection
from sender 1 for brake
booster -G201-
- Disconnect multi-pin
connection T47 from
ABS control module
(w/EDL) -J104-
- Connect test box
V.A.G 1598/36
- Check wiring for open
circuit between sender
1 for brake booster -
G201- multi-pin
connector and ABS
control module (w/EDL)
-J104- multi-pin
connector
Max. 1.5
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Test step 19: Continued on next
page.
Стр
. 32
из
38
Electrical check of Mark 60