01-111
Test table
Notes on test table
The socket designations of adapter V.A.G 1598/21 are identical to the control module -J104
contact designations in wiring diagram.
Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
If the readings obtained deviate from the specifications, carry out repair measure in the
right-hand part of the table.
Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Continuity checks with adapter set V.A.G 1594 A (bridging).
If the measured figures only deviate slightly from the specifications, clean sockets and
connectors of the testers and adapter cables (with contact spray G 000 700 04 ) and repeat
check. Before replacing components, check wiring and connections and also, particularly for
specifications of less than 10
, repeat resistance check on the component.
Стр
. 10
из
31
ABS, ABS/EDL and ABS/EDL/ASR ITT Mark 20 IE, electrical check