Water Distribution System
Water Distributors.
The water distributors are located under the freezer cover at the top of the
freezer. These distributors may require occasional or periodic cleaning to remove solids and foreign
particles accumulated from the make-up water. The frequency of this cleaning operation will
depend on the characteristics of the water supply. The cleaning operation is needed when the inside
diameter of a large proportion of the ice becomes irregular (due to channeling of water), or if some
of the ice is opaque, or if there is a noticeable decrease in ice capacity.
Tube Size
1”
1 1/4”
1 1/2”
Number of Water Distributors
156
102
72
TABLE 7-1
Number of Water Distributors Per Tube Size
To clean distributors, stop the unit and remove the freezer cover on top of the freezer. The water
distributors (one in each tube) may then be removed with pliers for cleaning. Use pliers on the
distributor’s top part with a twisting upward motion. Use care when removing distributors to avoid
distorting orifice holes or the body of the distributor. The distributors can be soaked in ice machine
cleaner to remove mineral buildup. Rinse distributors thoroughly before reinstalling and tap lightly
with a rubber mallet to seat them in the freezer tubes.
Tube Size
1”
1 1/4”
1 1/2”
Hole Size
1/16”-1/8”
Avg.
1/8”-3/16”
Avg.
1/4”-3/8”
Avg.
TABLE 7-2
Average Hole Size In Tube-Ice
®
Water Tank.
The production of opaque ice can indicate that the water in the water tank contains a
concentrated amount of solids or salts. Remove cover plate. Open drain valve (28). Clean tank
thoroughly by flushing out with a hose and scrubbing with a stiff brush. It may be necessary to
completely remove the water tank in order clean all surfaces. The tank has casters to simplify
removal. After cleaning, close drain (reinstall tank if necessary) and fill the water tank with fresh
water. When restarting the machine, be sure that the water pump is circulating water. It is possible
that air may have collected in the pump impeller housing and the pump may have to be stopped and
started several times to expel the air.
Freezer Cover.
A clear polycarbonate freezer cover is provided for visual inspection of the water
box and water distributors located at the top of the freezer. The cover should be removed and
cleaned if it becomes coated with deposits. Generally, if the freezer cover is coated with solids this
is a prime indicator that the other areas (i.e. water tank and distributors) also require cleaning.
! CAUTION !
The water distribution system is critical to proper machine operation.
Failure to maintain and clean water distribution components can
result in improper machine operation and compressor failure.
! CAUTION !
Summary of Contents for P18AL TUBE-ICE
Page 1: ...8 28 00 P18AL TUBE ICE MACHINE Manual Part Number 12A4171M09 Service Manual 5000 ...
Page 4: ......
Page 14: ...P18AL Service Manual INTRODUCTION 3 6 07 1 4 FIGURE 1 1 P18AL Front View ...
Page 15: ...P18AL Service Manual INTRODUCTION 3 6 07 1 5 FIGURE 1 2 P18AL Back View ...
Page 16: ...P18AL Service Manual INTRODUCTION 3 6 07 1 6 FIGURE 1 3 P18AL Left View ...
Page 17: ...P18AL Service Manual INTRODUCTION 3 6 07 1 7 FIGURE 1 4 P18AL Right View ...
Page 18: ...P18AL Service Manual INTRODUCTION 3 6 07 1 8 ...
Page 48: ...P18AL Service Manual ELECTRICAL CONTROLS 3 6 07 6 6 ...
Page 56: ...P18AL Service Manual MAINTENANCE 3 6 07 7 8 ...
Page 64: ...P18AL Service Manual TROUBLESHOOTING 3 6 07 8 8 ...
Page 76: ...P18AL Service Manual SERVICE OPERATIONS 3 6 07 9 12 FIGURE 9 3 Cutter Water Tank Assembly ...
Page 78: ...P18AL Service Manual TABLES CHARTS 3 6 07 10 1 10 Tables Charts ...