Technical specifications
24
Subject to modifications
US edition 2021/01
VOGT Air Lance Original operating manual
Contact:
+49(0)92 78-774 33-0
+49(0)92 78-774 33-11
www.vogt-tec.com
10
Technical specifications
The following tables show only standard device lengths. A large number of
special lengths are available on request.
Technical specifications for VOGT Air Lance VL 3.5/VL 3.5 K/VL 3.5 S
Type
VL 3�5
VL 3�5 K
VL 3�5 S
Total Length
130 cm
(51.2“)
47 cm
(18.5“)
132 cm
(52.0“)
Weight*
3.9 kg
(8.6 lb)
3.0 kg
(6.6 lb)
2.9 kg
(6.4 lb)
* The real weight can deviate from the information listed here by ±1 % for production reasons.
Designation
Value / Unit
Operating medium
Air
Operating pressure
3.0 to 10.0 bar (43 to 145 psi)
Evaluated sound
output level L
WA
(EN 15744/EN ISO 4871)
123 dB (+3 dB uncertainty) up to 7.0 bar (102
psi)
Evaluated emission
sound pressure level L
pa
(EN 15744/EN ISO 4871)
112 dB (+3 dB uncertainty) up to 7.0 bar (102
psi)
Inner hose diameter
At least 3/4”
Compressor/nozzle allocation
Compressor output
Nozzle
2.5 – 3.5 m³/min
Standard jet tube with nozzle
1.5 - 1.9 m³/min
Nozzle with 1-ring marking
2.0 - 2.9 m³/min
Nozzle with 2-ring marking
3.0 - 3.9 m³/min
Nozzle with 3-ring marking
4.0 - 6.0 m³/min
Nozzle with 4-ring marking